Actions

Difference between revisions of "TKIE Connections"

From Zenitel Wiki

(Input/Output Connections)
Line 1: Line 1:
 
[[File:TKIE-2.PNG|right|300px]]
 
[[File:TKIE-2.PNG|right|300px]]
<br style="clear:both;" />
+
__NOTOC__
 +
This article describes all Turbine Extended Kit connections.
  
{| border="1"
+
There are two RJ-45 ports located on the Turbine Extended Kit that are used for PoE/LAN Ethernet connection.
|Ethernet/Power|| 10/100 Mbps Ethernet RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
+
 
 +
There are 6 I/O connection options for the Turbine Extended Kit. These connections are used as digital input (eg. from a closing contact), digital output (5V), or LED driving (20mA max) for connecting sensors, indicators or integration to other systems.
 +
 
 +
{|border="1"
 +
|Ethernet/Power|| The Turbine Extended Kit supports Power over Ethernet (PoE, IEEE 802.3 a-f) where power can be drawn from either the spare line or signal line.*
 
|-
 
|-
|Secondary Power || 24 VDC (16 – 48 V) secondary power is provided from an external adapter.
+
|Secondary Power || If PoE is not available, the Turbine Extended Kit can be powered from a 24-48 VDC local power supply.**
 
|-
 
|-
|Relays || There is one Double Throw relay contact with 60W switching power. COM, NO, NC contacts are provided. Max: 250VAC/220VDC, 2A, 60W
+
|Relays || There are two Double Throw relay contacts with 60W switching power. COM, NO, NC contacts are provided.
 
|-
 
|-
|Input/Output || 6 general purpose I/Os are available. Each I/O can be configured as either input, output, or LED driver.  
+
|Input/Output || 6 I/Os are available. Each I/O can be configured as either input, output, or LED driver.  
 
|-
 
|-
 
|Audio Line Out || A balanced 600 ohm audio line out with induction loop signal
 
|Audio Line Out || A balanced 600 ohm audio line out with induction loop signal

Revision as of 14:22, 17 October 2016

TKIE-2.PNG

This article describes all Turbine Extended Kit connections.

There are two RJ-45 ports located on the Turbine Extended Kit that are used for PoE/LAN Ethernet connection.

There are 6 I/O connection options for the Turbine Extended Kit. These connections are used as digital input (eg. from a closing contact), digital output (5V), or LED driving (20mA max) for connecting sensors, indicators or integration to other systems.

Ethernet/Power The Turbine Extended Kit supports Power over Ethernet (PoE, IEEE 802.3 a-f) where power can be drawn from either the spare line or signal line.*
Secondary Power If PoE is not available, the Turbine Extended Kit can be powered from a 24-48 VDC local power supply.**
Relays There are two Double Throw relay contacts with 60W switching power. COM, NO, NC contacts are provided.
Input/Output 6 I/Os are available. Each I/O can be configured as either input, output, or LED driver.
Audio Line Out A balanced 600 ohm audio line out with induction loop signal
Note! Use cables crimped with ferrules for terminal block connectors
  • When the Turbine Kit is connected to the network, its IP address is automatically obtained from a DHCP server or an IP address in the range 169.254.x.x will be assigned.
  • To make the kit speak its IP address:
- connect a speaker to the speaker output
- connect a button to input 1
- press the button after startup
TKIESpeakIP.png


Power Supply

The Turbine Compact Kit supports Power over Ethernet (PoE, IEEE 802.3 a-f) where power can be drawn from either the spare line or signal line. If PoE is not available, the Turbine Compact Kit can be connected to a 24 VDC local power supply.

Network Connection

Turbine Extended Kit


There is one RJ-45 port located on the Turbine Compact Kit that is used for PoE/LAN Ethernet connection.

Optional Speaker/Microphone connector

Side connectors


Input/Output Connections

There are 6 I/O connection options for the Turbine Compact Kit. These connections can be used to interface with external I/O devices. The connections are typically used as digital input (eg. from a closing contact), digital output (5V), or LED driving (20mA max) for connecting sensors, indicators or integration to other systems.

See also Turbine Extended Board Connectors