Difference between revisions of "GPO Output configuration (ENA amplifier in SIP mode)"
From Zenitel Wiki
(No difference)
|
Latest revision as of 16:01, 26 June 2024
This article is related to configuration of GPO outputs from the ENA IP Network Amplifier used in SIP mode.
Contents
Event Triggers
Possible Event Triggers are:
- DTMF: Will trigger an event on received DTMF. The action will stay on until next event happens.
- Active Call: The station may in some situations have multiple calls, the active call is the call which has media/tone handling.
- Can filter so it only triggers the event on
- State: Ringing, Queued, In Call, On Hold
- Direction: Incoming, Outgoing or Incoming/Outgoing
- Channel: Channel 1, Channel 2, Input Channel
- Directory Number: Can either directory number or a range for example 100-199
- If the state In Call is selected, the output will stay set until the call has ended.
- Registration Failed: Event is triggered if registration failed. The output action will be cleared on registration success.
- Idle :Event is triggered when station goes back to Idle.
Event Actions
The Action controls an Output, and multiple outputs can be controlled in the same Event.
States can be: steady off, steady on and timed steady on.
Example
Trigger Output during call to specific number
In this example the output will be triggered only if the amplifier is in a call with the number 401.