Difference between revisions of "GPO Output configuration (ENA amplifier in SIP mode)"
From Zenitel Wiki
(Created page with "{{S}} This article is related to configuration of GPO outputs from the ENA IP Network Amplifiers used in SIP mode. thumb|left|700px <br style="cle...") |
|||
(5 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
{{S}} | {{S}} | ||
− | This article is related to configuration of GPO outputs from the ENA IP Network | + | This article is related to configuration of GPO outputs from the ENA IP Network Amplifier used in SIP mode. |
− | + | == Event Triggers == | |
[[File:ENA adv output.png|thumb|left|700px]] | [[File:ENA adv output.png|thumb|left|700px]] | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
− | + | Possible Event Triggers are: | |
− | Possible Event Triggers are | + | *'''DTMF:''' Will trigger an event on received DTMF. The action will stay on until next event happens. |
− | |||
− | *'''DTMF:''' | ||
− | |||
− | *'''Active Call | + | *'''Active Call''': The station may in some situations have multiple calls, the active call is the call which has media/tone handling. |
− | :The station may in some situations have multiple calls, the active call is the call which has media/tone handling. | ||
:Can filter so it only triggers the event on | :Can filter so it only triggers the event on | ||
Line 23: | Line 19: | ||
:If the state '''In Call''' is selected, the output will stay set until the call has ended. | :If the state '''In Call''' is selected, the output will stay set until the call has ended. | ||
− | *'''Registration Failed''' | + | *'''Registration Failed''': Event is triggered if registration failed. The output action will be cleared on registration success. |
− | :Event is triggered if registration failed. The output action will be cleared on registration success. | ||
− | *'''Idle''' | + | *'''Idle''' :Event is triggered when station goes back to Idle. |
− | :Event is triggered when station goes back to Idle. | ||
<br> | <br> |
Latest revision as of 16:01, 26 June 2024
This article is related to configuration of GPO outputs from the ENA IP Network Amplifier used in SIP mode.
Contents
Event Triggers
Possible Event Triggers are:
- DTMF: Will trigger an event on received DTMF. The action will stay on until next event happens.
- Active Call: The station may in some situations have multiple calls, the active call is the call which has media/tone handling.
- Can filter so it only triggers the event on
- State: Ringing, Queued, In Call, On Hold
- Direction: Incoming, Outgoing or Incoming/Outgoing
- Channel: Channel 1, Channel 2, Input Channel
- Directory Number: Can either directory number or a range for example 100-199
- If the state In Call is selected, the output will stay set until the call has ended.
- Registration Failed: Event is triggered if registration failed. The output action will be cleared on registration success.
- Idle :Event is triggered when station goes back to Idle.
Event Actions
The Action controls an Output, and multiple outputs can be controlled in the same Event.
States can be: steady off, steady on and timed steady on.
Example
Trigger Output during call to specific number
In this example the output will be triggered only if the amplifier is in a call with the number 401.