EX1-1a.PNG


Practice 1-1a:

Cards:

  • Insert the ASLT card in position 1.
  • Insert the AMC-IP card in position 7.

Power:

  • Connect the power source to the plug on the back of the exchange, marked 24 VAC IN
  • Connect the mains cable to the wall outlet
  • Observe the exchange starting

Coldstart:

  • Press and hold the coldstart button on the AMC-IP board
  • Press the reset button on the power card briefly
  • Keep the cold start button pressed at least 2 sec. after reset.
  • The AMC status LED will blink green when the boot is ready.