Line 9: | Line 9: | ||
** Press the call button | ** Press the call button | ||
** While the button is pressed, connect the IP Substation to the PoE switch | ** While the button is pressed, connect the IP Substation to the PoE switch | ||
− | ** Wait until the call LED of the station | + | ** Wait until the call LED of the station has flashed two times |
− | ** Release the call button for | + | ** Release the call button and wait for two new flashes |
− | ** Push the button briefly | + | ** Push the button briefly after the two flashes |
* Assign the PC an IP address in the range 169.254.x.x | * Assign the PC an IP address in the range 169.254.x.x | ||
* Connect the PC to the network switch | * Connect the PC to the network switch |
Revision as of 13:04, 13 February 2014
Station configuration
Configure the IP Substation
- Perform a "Factory Default" setting on the IP Substation:
- Press the call button
- While the button is pressed, connect the IP Substation to the PoE switch
- Wait until the call LED of the station has flashed two times
- Release the call button and wait for two new flashes
- Push the button briefly after the two flashes
- Assign the PC an IP address in the range 169.254.x.x
- Connect the PC to the network switch
- On the PC start a web browser, and enter the IP station address 169.254.1.100 in the address field
- Log in with Username: admin, password: alphaadmin
- Select CCoIP Configuration, and enter the following parameters:
- Connect the IP substation and the AlphaCom XE (Eth1) to the same network switch
Configure the AlphaCom XE
- In AlphaPro go to Users & Stations, and select physical number 39; 139 Station 39
- Use the section on the right and change the configuration as follows:
Call Button
- In AlphaPro, Users & Stations, select physical port 39. Then press the button DAK, and configure as follows:
- Send the changes to the AlphaCom XE
Troubleshooting
- If the IP station does not register, check the following:
- In AlphaWeb, System Configuration -> Filters, verify that port for IP Stations and VoIP Audio is enabled
- In AlphaWeb, System Configuration -> Licenses, verify that there are licenses installed for the IP stations