Revision as of 16:08, 6 April 2011

System configuration


Solution

Alarm Message Distribution (761)

  • Upload the standard english ASVP package to the AlphaCom:
From AlphaWeb, System Maintenance -> System Upgrade, Browse to the file asvp_en_06.00.apkg, then select Upload and then Install



  • By pressing a DAK key on the Main Guard, the prerecorded alarm message (8191) should be distributed to all stations (84)
  • Another DAK key should stop the message:
In AlphaPro, Users & Stations -> DAK, program two DAK keys to 761 + Group + Alarm message


NOTE: the 761 code is by default available only for SuperUser station (COS 16). Make the function code valid also for stations in COS 1:

In AlphaPro, Class Of Service, make the code 761 (feature 68) valid



  • Instead of using the standard alarm message, a new customized message available as wav file should be used:
From AlphaWeb, System Configuration-> selecy Message Group 30 and individ 1, then browse to the wav file and Upload



  • Instead of using the wav file, a new customized message should be recorded from a station:

On a SuperUser station, dial 8180 + 8191 + M to record.