Line 7: Line 7:
  
 
In AlphaPro, '''Users & Stations''', select station 6519 G. Galilei from the list box, and press the button '''Events'''. '''Insert''' a new event with the following properties:
 
In AlphaPro, '''Users & Stations''', select station 6519 G. Galilei from the list box, and press the button '''Events'''. '''Insert''' a new event with the following properties:
[[File:2-2a solution1.PNG|thumb|left|600px|The event 09 - Private Ringing goes ON when ringing starts, and OFF when ringing stops]]
+
[[File:2-2a solution1.PNG|thumb|left|600px|The event 09 - Private Ringing mode goes ON when ringing starts, and OFF when ringing stops]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
Line 15: Line 15:
 
In this case we need to split the lamp control in two separate events, one event to turn the lamp on, another event to turn it off.
 
In this case we need to split the lamp control in two separate events, one event to turn the lamp on, another event to turn it off.
  
When the private ringing starts, The event 09-Private Ringing goes ON:
+
 
[[File:2-2a solution2.PNG|thumb|left|600px|AlphaPro: Users & Stations window]]
+
[[File:2-2a solution2.PNG|thumb|left|600px|When the private ringing starts, The event 09-Private Ringing mode goes ON]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  

Revision as of 13:39, 21 February 2013

System configuration


Solution

Call indication, exercise 1

  • When calling G. Galilei a lamp (RCO 4) should be activated when the private ringing starts. (G. Galilei is in “Private” mode).
  • The lamp should be turned off when the private ringing stops.

In AlphaPro, Users & Stations, select station 6519 G. Galilei from the list box, and press the button Events. Insert a new event with the following properties:

The event 09 - Private Ringing mode goes ON when ringing starts, and OFF when ringing stops


Call indication, exercise 2

  • The customer changes his mind; the lamp should go on when the private ringing starts and stay on also during the conversation. When the conversation ends the lamp should be switched off. If the call is not answered, the relay must drop when the ringing times out. The lamp should not go on when G. Galilei makes a call, only when receiving a call.

In this case we need to split the lamp control in two separate events, one event to turn the lamp on, another event to turn it off.


When the private ringing starts, The event 09-Private Ringing mode goes ON



AlphaPro: Users & Stations window