Difference between revisions of "2-2c. CCTV with data (1) - Event Handler (practice)"
From Zenitel Wiki
(12 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | + | [[File:2-2c exercise.PNG|left|thumb|500px|System configuration]] | |
− | [[File:2-2c exercise.PNG]] | + | <br style="clear:both;" /> |
+ | |||
+ | '''Call buttons:''' | ||
+ | * Pressing the call button at the Entrance or at the SOS Point should generate a '''Call Request''' (623 + 101) to the Control Room. | ||
+ | |||
+ | |||
+ | '''CCTV Control:''' | ||
+ | *When a Call Request (= mail) is received at the Control Room, the AlphaCom should send ASCII text on the EDO port 1 to the CCTV system, telling which camera to connect to which monitor. | ||
+ | * The EDO output should be "C1M1" when station 107 is calling, and "C2M1" when station 108 is calling. | ||
+ | * The AlphaCom should be set as a "TCP Server", and TCP port number 4005 should be used for the communication (Hint: Remember to define the port in "Filters" setting). | ||
+ | * Use the software "PuTTY" to verify that the correct data is being transmitted from the AlphaCom (In PuTTY use the Connection type = "Raw"). | ||
+ | |||
+ | <br><br><br><br> | ||
+ | |||
+ | ---- | ||
+ | |||
+ | ===Related articles === | ||
+ | * [[2-2c. CCTV with data (1) - Event Handler (solution)]] | ||
+ | |||
+ | |||
[[Category: AlphaCom practice]] | [[Category: AlphaCom practice]] |
Latest revision as of 16:40, 27 September 2013
Call buttons:
- Pressing the call button at the Entrance or at the SOS Point should generate a Call Request (623 + 101) to the Control Room.
CCTV Control:
- When a Call Request (= mail) is received at the Control Room, the AlphaCom should send ASCII text on the EDO port 1 to the CCTV system, telling which camera to connect to which monitor.
- The EDO output should be "C1M1" when station 107 is calling, and "C2M1" when station 108 is calling.
- The AlphaCom should be set as a "TCP Server", and TCP port number 4005 should be used for the communication (Hint: Remember to define the port in "Filters" setting).
- Use the software "PuTTY" to verify that the correct data is being transmitted from the AlphaCom (In PuTTY use the Connection type = "Raw").