Actions

Difference between revisions of "2-2c. CCTV with data (1) - Event Handler (practice)"

From Zenitel Wiki

 
(5 intermediate revisions by the same user not shown)
Line 1: Line 1:
[[File:2-2c exercise.PNG]]
+
[[File:2-2c exercise.PNG|left|thumb|500px|System configuration]]
 +
<br style="clear:both;" />
  
 
'''Call buttons:'''
 
'''Call buttons:'''
Line 6: Line 7:
 
   
 
   
 
'''CCTV Control:'''
 
'''CCTV Control:'''
*When a Call Request (= mail) is received at the Control Room, the AlphaCom should send ASCII text on the EDO port 1 to the CCTV system, telling which camera to connect to which monitor. The AlphaCom should be set as a "TCP Server", and TCP port number 4005 should be used for the communication (Hint: Remember to define the port in "Filters" setting). The EDO output should be "C1M1" when station 107 is calling, and "C2M1" when station 108 is calling. Use the software "PuTTY" to verify (Protocol = "Raw").
+
*When a Call Request (= mail) is received at the Control Room, the AlphaCom should send ASCII text on the EDO port 1 to the CCTV system, telling which camera to connect to which monitor.  
 +
* The EDO output should be "C1M1" when station 107 is calling, and "C2M1" when station 108 is calling.
 +
* The AlphaCom should be set as a "TCP Server", and TCP port number 4005 should be used for the communication (Hint: Remember to define the port in "Filters" setting).  
 +
* Use the software "PuTTY" to verify that the correct data is being transmitted from the AlphaCom (In PuTTY use the Connection type = "Raw").
 +
 
 +
<br><br><br><br>
 +
 
 +
----
 +
 
 +
===Related articles ===
 +
* [[2-2c. CCTV with data (1) - Event Handler (solution)]]
  
  
  
 
[[Category: AlphaCom practice]]
 
[[Category: AlphaCom practice]]

Latest revision as of 16:40, 27 September 2013

System configuration


Call buttons:

  • Pressing the call button at the Entrance or at the SOS Point should generate a Call Request (623 + 101) to the Control Room.


CCTV Control:

  • When a Call Request (= mail) is received at the Control Room, the AlphaCom should send ASCII text on the EDO port 1 to the CCTV system, telling which camera to connect to which monitor.
  • The EDO output should be "C1M1" when station 107 is calling, and "C2M1" when station 108 is calling.
  • The AlphaCom should be set as a "TCP Server", and TCP port number 4005 should be used for the communication (Hint: Remember to define the port in "Filters" setting).
  • Use the software "PuTTY" to verify that the correct data is being transmitted from the AlphaCom (In PuTTY use the Connection type = "Raw").