Actions

Difference between revisions of "IP Video Door Station - 1401110200"

From Zenitel Wiki

(PhonerLite SIP Client)
(Milestone)
Line 88: Line 88:
  
 
=Setup with 3rd party Video devices=
 
=Setup with 3rd party Video devices=
==Milestone==
 
It is assumed that a Milestone XProtect system is already installed and up and running. The latest Milestone XProtect Professional and Smart client can be downloaded from Milestonesys.com.
 
 
The version used in the examples that follows is XprotectPro V8.1a
 
 
Open the XProtect Professional Management Application by double clicking the desktop icon. Expand the mennu tree strcture and right click ''Hardware Devices''. Select '''Add New Hardware Device'''
 
[[File:Milestone4.PNG|left|thumb|500px]]
 
<br style="clear:both;" />
 
--------------------------
 
Choose '''Manual''' as the hardware detection method.
 
[[File:Milestone5.PNG|left|thumb|500px]]
 
<br style="clear:both;" />
 
--------------------------
 
*1 Enable ''Use''
 
*2 Type in the IP address of the camera in the ''Address'' field
 
*3 Select username '''admin''' from the dropdown box under ''User Name''
 
*4 Enter the default IP Video Door Station camera password: 1234 in the ''Password field''
 
*5 In the ''Hardware Driver'' dropdown box, scroll down and select '''Universal Driver'''
 
*6 Repeat for 1-5 the next camera(s)
 
*7 Click '''Next''', followed by '''Finish''' in the next window.
 
[[File:Milestone6.PNG|left|thumb|500px]]
 
<br style="clear:both;" />
 
--------------------------
 
After adding the new camera(s) to the device list, they should appear in the tree structure under ''Cameras and Storage Information''. Right click the IP Video Station camera and select '''Properties'''
 
[[File:Milestone3.PNG|left|thumb|500px]]
 
<br style="clear:both;" />
 
--------------------------
 
If the image in the preview window is visible, no more actions are required.
 
 
If there is no image shown from the camera, click on the ''Camera Settings...'' button.
 
[[File:Milestone2.PNG|left|thumb|500px]]
 
<br style="clear:both;" />
 
--------------------------
 
In the Video Properties set:
 
*1 Codec: JPEG
 
*2 Streaming mode: HTTP
 
*3 Delivery mode: Multipart stream
 
*4 Retrieval mode: Streaming
 
*5 Connection URI: <nowiki>http://<camera IP address>/mjpg/video.mjpg</nowiki>
 
*6 Click ''Preview Image'' to verify that the image is shown, followed by clicking ''OK''.
 
[[File:Milestone1.PNG|left|thumb|500px]]
 
<br style="clear:both;" />
 
--------------------------
 
 
  
  

Revision as of 11:37, 5 November 2014

IP Video Station, item 1401110200

The STENTOFON Vandal Resistant IP Video Station (item 1401110200) is tough, durable and resilient, and designed for use in the harshest of environments. The station is typically used as a communication, information or emergency point and connects directly to the IP network making it easy to deploy – anywhere and at any distance. Designed for CCoIP® the station offers a set of critical communication features such as integrated firewall, group call, call priority and over-ride, to name just a few. This enables you to deliver instant, efficient and secure voice, video and data services in an IP environment.

Installation

See article: IP Station Installationxx

Station Board Connectors and LED Indications

See article: IP Station Board Connections and Indications

IP Station Configuration

See article: IP_Station_Configuration#Configuration_in_IP-StationWeb

Reset to factory settings

See article: IP Station Restore Factory Defaults

Software Upgrade

See article: IP Station Software upgrade

Dimensions

See article: IP Stations Dimensions and Mounting Instructions

Camera configuration

Connect to the camera using a webbrowser on default IP address 169.254.1.101.

In the menu that appears, click System Settings, and you will be asked to login:

Username: admin
Password: 1234

Set to factory default:

CP-Cam Factory Reset

This should be carried out only by experienced technicians. The customer is liable for damages caused by improper opening of the housing.

If the entered IP address is unknown, it is possible to reset the address to 169.254.1.101 using the DIP switch. To proceed, the unit must be opened.

Note: A change of the IP address is made via the web interface of the CP-CAM.

The procedure is as follows:

1. Open the CP-CAM so the two DIP switches are accessible ( see picture ).
2. Note the switch position and then turn both switches to „OFF“.
3. Connect PC with the IP number range 169.254.1.xxx and set the desired IP address in the web interface.
4. Turn switch positions back to original positions.
5. Close housing properly.
CP-CAM.PNG


Axis Factory Reset

To restore the factory settings, proceed as follows:

1. Disconnect the camera from the power supply and ethernet.
2. Remove the four screws securing the rear cover and remove it.
3. Keep the Control button pressed while you restore the power supply.
4. Hold down the button for about 15 seconds until the status LED is yellow flashing.
5. Release the Control Button. The process is complete when the status LEDs light up green.
Axis.PNG


If no DHCP server is active on your network the new default IP is 192.168.0.90.
The new default user is root with password pass

Setup with STENTOFON Video Display Station

To configure the STENTOFON Video Display Station please see: IP Desktop Station with Video Display - 1408001635

This chapter describes the steps for configuring the CP-Cam:

From the Main Menu select System Settings > Network

1. Under section IP-SETUP, set IP-SETUP Type to Manual
IP-VideoDoorStation1.png


2. Enter a static IP adresss, Netmask, Gateway and DNS
3. Under section System, set Authentication required for Picture/Video to No
IP-VideoDoorStation2.png


4. Click Save Changes at the bottom of the page



From the Main Menu select System Settings > Camera

1. Under section Settings, set Mode to Custom
2. Set Res X to 320
3. Set Res Y to 240
IP-VideoDoorStation3.png


4. Under section Settings, set Frames per Second (Sensor) to 15
IP-VideoDoorStation4.png


Setup with 3rd party Video devices