Actions

Difference between revisions of "TFIX - Installation Solutions"

From Zenitel Wiki

(Multiple TFIX'es with beacon)
(Multiple TFIX'es with beacon)
Line 12: Line 12:
 
== Multiple TFIX'es with beacon ==
 
== Multiple TFIX'es with beacon ==
 
Multiple TFIX'es with beacon in the EX zone, where all the controlling equipment is located in the safe zone in closed cabinets in a more convenient placements out in the field. <br/>
 
Multiple TFIX'es with beacon in the EX zone, where all the controlling equipment is located in the safe zone in closed cabinets in a more convenient placements out in the field. <br/>
 +
Each cabinet consist of:
 +
* 1 Turbine extended kit; TKIE
 +
* 1 IP Station License
 +
* 1 Turbine Relay board; TA-10
 +
* 1 Power supply; 24VDC or 230VAC
 +
* 1 Flowire unit; FCDC
 +
* 1 24VDC PSU for the Flowire
 +
 
[[File:TFIX Beacon Multiple2.png|thumb|left|500px]]
 
[[File:TFIX Beacon Multiple2.png|thumb|left|500px]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
 +
 +
----
  
 
Multiple TFIX'es with beacon in the EX zone, where all controlling equipment is located in the server room. <br/>
 
Multiple TFIX'es with beacon in the EX zone, where all controlling equipment is located in the server room. <br/>
 +
For every sixth TFIX with beacon you need:
 +
* 1 Turbine compact Kit; [[TKIS-2]]
 +
* 1 IP Station License
 +
* 1 Multi-relay board; [[MRBD]]
 +
* 1 24VDC PSU: for the MRBD
 +
* 1 Flowire unit; FCDC
 +
* 1 24VDC PSU for the Flowire
 +
* 6 Relay boxes; [[IRR-3]]
 +
* 6 Beacons; BEX24O or BEX230O
 +
* 6 Powers supplies; 24VDC or 230VAC
 +
 
[[File:TFIX Beacon Multiple1.png|thumb|left|500px]]
 
[[File:TFIX Beacon Multiple1.png|thumb|left|500px]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
 
[[File:Beacon and IRR-3.png|thumb|left|500px|Detailed connection diagram]]
 
[[File:Beacon and IRR-3.png|thumb|left|500px|Detailed connection diagram]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />

Revision as of 11:44, 2 October 2015

ARTICLE UNDER CONSTRUCTION!!!

TFIX station with beacon

A beacon lamp can be used to indicate an incoming call or PA announcement.

Single TFIX with beacon

A single TFIX with beacon in the EX zone, where all the controlling equipment is located in the safe zone, either in the server room, or in a closed cabinet in a more convenient placement out in the field.

TFIX Beacon Single.png


Multiple TFIX'es with beacon

Multiple TFIX'es with beacon in the EX zone, where all the controlling equipment is located in the safe zone in closed cabinets in a more convenient placements out in the field.
Each cabinet consist of:

  • 1 Turbine extended kit; TKIE
  • 1 IP Station License
  • 1 Turbine Relay board; TA-10
  • 1 Power supply; 24VDC or 230VAC
  • 1 Flowire unit; FCDC
  • 1 24VDC PSU for the Flowire
TFIX Beacon Multiple2.png



Multiple TFIX'es with beacon in the EX zone, where all controlling equipment is located in the server room.
For every sixth TFIX with beacon you need:

  • 1 Turbine compact Kit; TKIS-2
  • 1 IP Station License
  • 1 Multi-relay board; MRBD
  • 1 24VDC PSU: for the MRBD
  • 1 Flowire unit; FCDC
  • 1 24VDC PSU for the Flowire
  • 6 Relay boxes; IRR-3
  • 6 Beacons; BEX24O or BEX230O
  • 6 Powers supplies; 24VDC or 230VAC
TFIX Beacon Multiple1.png


Detailed connection diagram