Difference between revisions of "TA-10"
From Zenitel Wiki
(→Connections) |
(→Configuration) |
||
Line 17: | Line 17: | ||
===<u>Configuration</u>=== | ===<u>Configuration</u>=== | ||
+ | In AlphaCom, the two relays must be mapped in the RCO table as pin 9 and pin 10. See [[RCO - Remote Control Output]] for more details. | ||
===<u>Dimensions</u>=== | ===<u>Dimensions</u>=== |
Revision as of 14:08, 3 January 2017
Highlights
- Designed for use with Turbine Industrial stations TFIE-x, and the Turbine kits TKIE-x
- Dual high-power relays (DPDT)
- Up to 400VAC /48 VDC per relay
- Up to 6A current per relay
- Heavy-duty spring-loaded terminals with spare grounding terminals
- Powered by Turbine Industrial stations (TFIE-x) or Turbine Extended Kit (TKIE-x)
Connection
- Use the cable that comes with the TA-10, and connect one end to the Turbine Extended Board (Connector J2), and the other end to the TA-10 board as indicated in the drawing below
Configuration
In AlphaCom, the two relays must be mapped in the RCO table as pin 9 and pin 10. See RCO - Remote Control Output for more details.
Dimensions
Dimensions (WxHxD) | Weight | |
TA-10 | 100 x 50 x 40 mm | 0.1 kg |