Actions

Difference between revisions of "ENA Amplifier - Monitoring"

From Zenitel Wiki

Line 2: Line 2:
 
<br>
 
<br>
 
== What can be supervised?==
 
== What can be supervised?==
Internal supervision of:
 
 
* '''Temperatures'''. A number of temperature sensors in the ENA amplifier will generate error report if the temperature is outside valid range. Monitored by default.  
 
* '''Temperatures'''. A number of temperature sensors in the ENA amplifier will generate error report if the temperature is outside valid range. Monitored by default.  
 
* '''AC Power and/or DC Power'''. Monitors the precense of the external power source. Monitoring must enabled in [[ENA_Configuration_-_AlphaCom_mode#Advanced_Config|Monitoring and Lines > Advanced Config, Internal Power Monitoring]] section
 
* '''AC Power and/or DC Power'''. Monitors the precense of the external power source. Monitoring must enabled in [[ENA_Configuration_-_AlphaCom_mode#Advanced_Config|Monitoring and Lines > Advanced Config, Internal Power Monitoring]] section

Revision as of 15:01, 9 April 2018

AlphaCom icon 300px.png

The ENA Amplifier provides extensive monitoring capabilities.


What can be supervised?


Error reporting

  • Fault Relay: The Fault Relay on the back of the amplifier will trigger whenever there is an error. The relay will remain triggered as long as one or more errors are present.
  • Amplifier GUI display: The Amplifier GUI display will indicate with a red exclamation mark if there are any errors. Use the Menu Selecetion Knob in front of the amplifier to navigate to Service > Local Message List to view current error messages
  • Amplifier web interface: In the Faults section in the Monitoring and Lines > Status menu there is a live update of current active faults. The page is automatically refreshed every 10 seconds.
  • AlphaCom System Log: Amplifier errors are reported to the AlphaCom, which will forward the error reports via the System Log. Log data can be stored in a local log file on the AMC-IP board, or sent to external log recipient via SysLog, E-Mail or SNMP trap.
  • AlphaCom Event Handler: Amplifier errors are reported by the Event Handler of the AlphaCom, event 43 - Station Fault Report. One can use the "subevent" to filter on specific fault types.
  • SNMP Traps - from Amplifier: The amplifier can be configured to report errors as SNMP Traps, see SNMP Settings