Actions

Difference between revisions of "INCA Station Restore Factory Defaults"

From Zenitel Wiki

(Restore with Activated DHCP)
 
(51 intermediate revisions by 3 users not shown)
Line 1: Line 1:
An IP Station may have to be reset to its original factory default settings if, for instance, the password to the webserver is forgotten.
+
{{APS}}
 +
== Applicable for stations ==
 +
* IP Substations - [[Weather and Vandal Resistant IP Substation - 1008041100|1008041100]]/[[Weather and Vandal Resistant IP Substation for 3 gang Back Box - 1008051000|1008051000]]
 +
* IP Video Door Stations - [[IP Video Door Station - 1401110100|1401110100]]/[[IP Video Door Station - 1401110200|1401110200]]
 +
<div style="text-align:left;"> <youtube width="300" height="180">W_YbTuXvr1w</youtube>  </div>
 +
<br>
 +
<div style="text-align:left;"> <youtube width="300" height="180">bJhq8uyTP24</youtube>  </div>
  
The defaults can be either be set to Static IP or Activated DHCP (when there are many new IP Substations in an installation).
 
  
== Restore to Factory Default for IP Stations without Display ==
+
==Procedure ==
This procedure is the recommended procedure for all IP Stations without Display:
+
When loading factory defalt settings, the unit can be set to use either '''Static IP''' or '''DHCP'''.  
* IP Substations - [[Weather and Vandal Resistant IP Substation - 1008041100|1008041100]]/[[Weather and Vandal Resistant IP Substation for 3 gang Back Box - 1008051000|1008051000]]
+
[[File:Load Defaults without Display - 1.PNG|thumb|right|200px]]
* IP Substation Kit - [[IP Substation Kit - 1008090200|1008090200]]
 
* [[IP Master Station Kit - 1008093000]] if ''no'' Display is connected.
 
* IP Video Door Stations - [[IP Video Door Station - 1401110100|1401110100]]/[[IP Video Door Station - 1401110200|1401110200]]
 
<br/>
 
The procedure ''can'' also be applied to:
 
* The [[IP Substation Kit - 1008090200]] if a button is connected to Input 1.
 
* The IP Dual Display - [[IP Dual Display Station - 1008007000|1008007000]] by using the Privacy button. (In the procedure below, use the Privacy button when the procedure says "Call button").
 
<br/>
 
The Factory Default procedure can be used to either set the station to use a Static IP address, or to use IP address from a DHCP server.
 
=== Restore with Static IP ===
 
[[File:Load Defaults without Display - 1.PNG|right|300px]]
 
# While pressing the call button, power up the substation.
 
# When the substation LED starts blinking, release the call button '''after exactly 2 blinks'''.
 
# Let the LED blink for '''exactly 2 more times''', then press the button again.
 
# Keep the button pressed until the LED '''blinks fast 2 times''' indicating a successful reset with static IP.
 
# Release the button and the substation will restart with the factory default settings.
 
  
{| class="wikitable"
+
[[File:Load Defaults without Display - 2.PNG|right|thumb|200px]]
!style="background:#ffdead" colspan="2"|Factory default values
+
# While pressing the call button, power up the station and keep the button pressed.
|-
+
# Release the button '''after exactly 2 flashes''' of the LED.
| Station Mode || align=center | '''Pulse'''
+
# Let the LED flash for '''exactly 2 more times''' (Static IP) or '''exactly 4 more times''' (DHCP), then press the button again.
|-
+
# Keep the button pressed until the LED '''flashes fast 2 time'''s (Static IP) or '''flashes fast 4 times''' (DHCP) indicating a successful reset.
| Station IP address || align=center | '''169.254.1.100'''
+
# Release the button and the station will restart with the factory default settings.
|-
+
<br>
| AlphaCom IP address || align=center | '''169.254.1.5'''
 
|-
 
| Username* || align=center | '''admin'''
 
|-
 
| Password* || align=center | '''alphaadmin'''
 
|-
 
|}
 
  
* Software 01.06 and earlier: '''ADMIN/alphacom''')
+
== Factory default values ==
 +
*Station Mode: '''Pulse'''
 +
*Station IP address: '''169.254.1.100''' (Static) or '''DHCP'''
 +
*Username: '''admin'''
 +
*Password: '''alphaadmin'''
  
=== Restore with Activated DHCP ===
 
[[File:Load Defaults without Display - 2.PNG|right|300px]]
 
The DHCP option is available from software version 01.07.<br/>
 
* While pressing the call button, power up the substation.
 
* When the substation LED starts blinking, release the call button '''after exactly 2 blinks'''.
 
* Let the LED blink for '''exactly 4 more times''', then press the button again.
 
* Keep the button pressed until the LED '''blinks fast 4 times''' indicating a successful reset with activated DHCP.
 
* Release the button and the substation will restart with the factory default settings.
 
  
{| class="wikitable"
 
!style="background:#ffdead" colspan="2"|Factory default values
 
|-
 
| Station Mode || align=center | '''Pulse'''
 
|-
 
| Station IP address || align=center | '''determined by DHCP server'''
 
|-
 
| AlphaCom IP address || align=center | '''169.254.1.5'''
 
|-
 
| Username* || align=center | '''admin'''
 
|-
 
| Password* || align=center | '''alphaadmin'''
 
|-
 
|}
 
  
* Software 01.06 and earlier: '''ADMIN/alphacom''')
+
{{note| Software 01.06 and earlier: Username/password is '''ADMIN/alphacom''' }}
  
 
[[Category: INCA - Restore Factory Defaults and Software Upgrade]]
 
[[Category: INCA - Restore Factory Defaults and Software Upgrade]]

Latest revision as of 13:16, 15 May 2018

APS.png

Applicable for stations



Procedure

When loading factory defalt settings, the unit can be set to use either Static IP or DHCP.

Load Defaults without Display - 1.PNG
Load Defaults without Display - 2.PNG
  1. While pressing the call button, power up the station and keep the button pressed.
  2. Release the button after exactly 2 flashes of the LED.
  3. Let the LED flash for exactly 2 more times (Static IP) or exactly 4 more times (DHCP), then press the button again.
  4. Keep the button pressed until the LED flashes fast 2 times (Static IP) or flashes fast 4 times (DHCP) indicating a successful reset.
  5. Release the button and the station will restart with the factory default settings.


Factory default values

  • Station Mode: Pulse
  • Station IP address: 169.254.1.100 (Static) or DHCP
  • Username: admin
  • Password: alphaadmin


Note icon Software 01.06 and earlier: Username/password is ADMIN/alphacom