Actions

Difference between revisions of "INCA Station Restore Factory Defaults"

From Zenitel Wiki

 
(8 intermediate revisions by one other user not shown)
Line 3: Line 3:
 
* IP Substations - [[Weather and Vandal Resistant IP Substation - 1008041100|1008041100]]/[[Weather and Vandal Resistant IP Substation for 3 gang Back Box - 1008051000|1008051000]]
 
* IP Substations - [[Weather and Vandal Resistant IP Substation - 1008041100|1008041100]]/[[Weather and Vandal Resistant IP Substation for 3 gang Back Box - 1008051000|1008051000]]
 
* IP Video Door Stations - [[IP Video Door Station - 1401110100|1401110100]]/[[IP Video Door Station - 1401110200|1401110200]]
 
* IP Video Door Stations - [[IP Video Door Station - 1401110100|1401110100]]/[[IP Video Door Station - 1401110200|1401110200]]
* [[IP Master Station Kit - 1008093000]] - A push button must be connected between pin 1 and pin 4 on connector P4.
+
<div style="text-align:left;"> <youtube width="300" height="180">W_YbTuXvr1w</youtube>  </div>
* The [[IP Substation Kit - 1008090200]] - A push button must be connected between pin 1 and pin 4 on connector P4.
 
<div style="text-align:left;"> <youtube width="300" height="180">hZkqvww2ub0</youtube>  </div>
 
 
<br>
 
<br>
<div style="text-align:left;"> <youtube width="300" height="180">-RDBOLvI-lo</youtube>  </div>
+
<div style="text-align:left;"> <youtube width="300" height="180">bJhq8uyTP24</youtube>  </div>
  
 
== Preparations of Station kit ==
 
Station kits require a push button to be connected between pins 1 and 4
 
[[File:Load Defaults without KEY.PNG|left|thumb|300px|Uush button between pin 1 (Key1) and 4 (COM)]]
 
<br style="clear:both;" />
 
  
 
==Procedure ==
 
==Procedure ==
 
When loading factory defalt settings, the unit can be set to use either '''Static IP''' or '''DHCP'''.  
 
When loading factory defalt settings, the unit can be set to use either '''Static IP''' or '''DHCP'''.  
[[File:Load Defaults without Display - 1.PNG|right|200px]]
+
[[File:Load Defaults without Display - 1.PNG|thumb|right|200px]]
<br>
+
 
[[File:Load Defaults without Display - 2.PNG|right|200px]]
+
[[File:Load Defaults without Display - 2.PNG|right|thumb|200px]]
 
# While pressing the call button, power up the station and keep the button pressed.
 
# While pressing the call button, power up the station and keep the button pressed.
 
# Release the button '''after exactly 2 flashes''' of the LED.
 
# Release the button '''after exactly 2 flashes''' of the LED.
Line 25: Line 18:
 
# Keep the button pressed until the LED '''flashes fast 2 time'''s (Static IP) or '''flashes fast 4 times''' (DHCP) indicating a successful reset.
 
# Keep the button pressed until the LED '''flashes fast 2 time'''s (Static IP) or '''flashes fast 4 times''' (DHCP) indicating a successful reset.
 
# Release the button and the station will restart with the factory default settings.
 
# Release the button and the station will restart with the factory default settings.
 +
<br>
  
 
== Factory default values ==
 
== Factory default values ==

Latest revision as of 13:16, 15 May 2018

APS.png

Applicable for stations



Procedure

When loading factory defalt settings, the unit can be set to use either Static IP or DHCP.

Load Defaults without Display - 1.PNG
Load Defaults without Display - 2.PNG
  1. While pressing the call button, power up the station and keep the button pressed.
  2. Release the button after exactly 2 flashes of the LED.
  3. Let the LED flash for exactly 2 more times (Static IP) or exactly 4 more times (DHCP), then press the button again.
  4. Keep the button pressed until the LED flashes fast 2 times (Static IP) or flashes fast 4 times (DHCP) indicating a successful reset.
  5. Release the button and the station will restart with the factory default settings.


Factory default values

  • Station Mode: Pulse
  • Station IP address: 169.254.1.100 (Static) or DHCP
  • Username: admin
  • Password: alphaadmin


Note icon Software 01.06 and earlier: Username/password is ADMIN/alphacom