Difference between revisions of "INCA Station Restore Factory Defaults"
From Zenitel Wiki
(→Preparations of Station kit) |
|||
Line 6: | Line 6: | ||
<br> | <br> | ||
<div style="text-align:left;"> <youtube width="300" height="180">bJhq8uyTP24</youtube> </div> | <div style="text-align:left;"> <youtube width="300" height="180">bJhq8uyTP24</youtube> </div> | ||
+ | |||
==Procedure == | ==Procedure == |
Latest revision as of 13:16, 15 May 2018
Applicable for stations
- IP Substations - 1008041100/1008051000
- IP Video Door Stations - 1401110100/1401110200
Procedure
When loading factory defalt settings, the unit can be set to use either Static IP or DHCP.
- While pressing the call button, power up the station and keep the button pressed.
- Release the button after exactly 2 flashes of the LED.
- Let the LED flash for exactly 2 more times (Static IP) or exactly 4 more times (DHCP), then press the button again.
- Keep the button pressed until the LED flashes fast 2 times (Static IP) or flashes fast 4 times (DHCP) indicating a successful reset.
- Release the button and the station will restart with the factory default settings.
Factory default values
- Station Mode: Pulse
- Station IP address: 169.254.1.100 (Static) or DHCP
- Username: admin
- Password: alphaadmin