− | The Station Menu is available when the IP Station is | + | The Station Menu is available in both Pulse and SIP mode. But in Alphacom mode it is only available when the IP Station is offline mode. i.e. not registered to the server. |
'''See video:''' | '''See video:''' |
Revision as of 13:19, 15 May 2018
This procedure is the recommended procedure for all IP Stations with Display.
The Station Menu is available in both Pulse and SIP mode. But in Alphacom mode it is only available when the IP Station is offline mode. i.e. not registered to the server.
See video:
Procedure
- Make sure the IP Station is disconnected from the AlphaCom XE exchange.
- Press the Setup button beneath the display
- Enter the password 1851 and press the Ok button.
- Navigate to Load defaults and press the Sel button.
- Press the Sel button to load factory defaults.
Factory default values
The station will now restart with factory settings:
- Station Mode: Pulse
- Station IP address: 169.254.1.100
- Username: admin
- Password: alphaadmin
This procedure may also be applied to the IP Master Station Kit - 1008093000 if a Display is connected. |