Difference between revisions of "INCA Station Kit Restore Factory Defaults"
From Zenitel Wiki
m (1 revision imported) |
|||
Line 3: | Line 3: | ||
* IP Substation Kit - [[IP Substation Kit - 1008090200|1008090200]] | * IP Substation Kit - [[IP Substation Kit - 1008090200|1008090200]] | ||
* IP Master Station Kit [[IP Master Station Kit - 1008093000|100809300]] | * IP Master Station Kit [[IP Master Station Kit - 1008093000|100809300]] | ||
+ | |||
+ | <div style="text-align:left;"> <youtube width="300" height="180">WP9m-DG0hMU</youtube> </div> | ||
The unit can be set to use either '''Static IP''' or '''DHCP'''. On the rear side of the PCB there is a red status LED. Pay attention to this LED during the restore procedure: | The unit can be set to use either '''Static IP''' or '''DHCP'''. On the rear side of the PCB there is a red status LED. Pay attention to this LED during the restore procedure: | ||
Line 8: | Line 10: | ||
[[File:Load Defaults without KEY.PNG|right|thumb|800px|Connect a push button between pins 1 and 4]] | [[File:Load Defaults without KEY.PNG|right|thumb|800px|Connect a push button between pins 1 and 4]] | ||
+ | == Procedure == | ||
# Connect a push button ('''KEY1''') between pin 1 and 4 on the P4 connector. | # Connect a push button ('''KEY1''') between pin 1 and 4 on the P4 connector. | ||
# While pressing the button, power up the station kit and keep the button pressed. | # While pressing the button, power up the station kit and keep the button pressed. | ||
Line 16: | Line 19: | ||
− | + | == Factory default values == | |
− | Factory default values | ||
*Station Mode: '''Pulse''' | *Station Mode: '''Pulse''' | ||
*Station IP address: '''169.254.1.100''' or '''DHCP''' | *Station IP address: '''169.254.1.100''' or '''DHCP''' |
Revision as of 13:24, 15 May 2018
This procedure is applicable for:
- IP Substation Kit - 1008090200
- IP Master Station Kit 100809300
The unit can be set to use either Static IP or DHCP. On the rear side of the PCB there is a red status LED. Pay attention to this LED during the restore procedure:
Procedure
- Connect a push button (KEY1) between pin 1 and 4 on the P4 connector.
- While pressing the button, power up the station kit and keep the button pressed.
- Release the button after exactly 2 flashes of the LED.
- Let the LED flash for exactly 2 more times (Static IP) or exactly 4 more times (DHCP), then press the button again.
- Keep the button pressed until the LED flashes fast 2 times (Static IP) or flashes fast 4 times (DHCP) indicating a successful reset.
- Release the button and the station will restart with the factory default settings.
Factory default values
- Station Mode: Pulse
- Station IP address: 169.254.1.100 or DHCP
- Username: admin
- Password: alphaadmin