Actions

Difference between revisions of "INCA Station Kit Restore Factory Defaults"

From Zenitel Wiki

(Restore with Static IP)
 
(18 intermediate revisions by 3 users not shown)
Line 1: Line 1:
Restore to Factory Default for IP Stations without Display and Key:
+
{{APS}}
 +
This procedure is applicable for:
 +
* IP Substation Kit - [[IP Substation Kit - 1008090200|1008090200]]
 
* IP Master Station Kit [[IP Master Station Kit - 1008093000|100809300]]
 
* IP Master Station Kit [[IP Master Station Kit - 1008093000|100809300]]
* IP Substation Kit - [[IP Substation Kit - 1008090200|1008090200]]
 
* IP Speaker - [[IP Ceiling Loudspeaker - 1401002100|1401002100]]/[[IP Horn Loudspeaker - 1401002500|1401002500]]
 
* IP Heavy Duty - [[IP Heavy Duty Station - 1008072200|1008072200]]
 
 
 
For IP Master Station kits with display, see: [[INCA Display Station Restore Factory Defaults]]
 
 
The Factory Default can be either set to Static IP 169.254.1.100 or activate DHCP.
 
  
Connect a push button ('''KEY1''') between pin 1 and 4 on the P4 connector.
+
<div style="text-align:left;"> <youtube width="300" height="180">WP9m-DG0hMU</youtube>  </div>
  
[[File:Load Defaults without KEY.PNG|left]]
 
<br style="clear:both;" />
 
  
--------
+
The unit can be set to use either '''Static IP''' or '''DHCP'''. On the rear side of the PCB there is a red status LED. Pay attention to this LED during the restore procedure:
  
=== Restore with Static IP ===
+
[[File:Load Defaults without KEY.PNG|right|thumb|800px|Connect a push button between pins 1 and 4]]
# While pressing the button, power up the station kit.
 
# When the station kit LED starts blinking, release the button '''after exactly 2 blinks'''.
 
# Let the LED blink for '''exactly 2 more times''', then press the button again.
 
# Keep the button pressed until the LED '''blinks fast 2 times''' indicating a successful reset with static IP.
 
# Release the button and the station kit will restart with the factory default settings.
 
  
<u>'''Factory default values:'''</u>
+
== Procedure ==
* Station Mode: '''Pulse'''
+
# Connect a push button ('''KEY1''') between pin 1 and 4 on the P4 connector.
* Station IP address: '''169.254.1.100'''
+
# While pressing the button, power up the station kit and keep the button pressed.
* AlphaCom IP address: '''169.254.1.5'''
+
# Release the button '''after exactly 2 flashes''' of the LED.
* Username: '''admin''' (Software 01.06 and earlier: '''ADMIN''')
+
# Let the LED flash for '''exactly 2 more times''' (Static IP) or '''exactly 4 more times''' (DHCP), then press the button again.
* Password: '''alphaadmin''' (Software 01.06 and earlier: '''alphacom''')
+
# Keep the button pressed until the LED '''flashes fast 2 times''' (Static IP) or '''flashes fast 4 times''' (DHCP) indicating a successful reset.
 +
# Release the button and the station will restart with the factory default settings.
  
------
 
  
=== Restore with Activated DHCP ===
+
== Factory default values ==
The DHCP option is available from software version 01.07.
+
*Station Mode: '''Pulse'''
# While pressing the button, power up the station kit.
+
*Station IP address: '''169.254.1.100''' or '''DHCP'''
# When the station kit LED starts blinking, release the button '''after exactly 2 blinks'''.
+
*Username: '''admin'''
# Let the LED blink for '''exactly 4 more times''', then press the button again.
+
*Password: '''alphaadmin'''
# Keep the button pressed until the LED '''blinks fast 4 times''' indicating a successful reset with activated DHCP.
 
# Release the button and the station kit will restart with the factory default settings.
 
  
'''Factory default values:'''
 
* Station IP address: (determined by DHCP server)
 
* AlphaCom IP address: '''169.254.1.5'''
 
* Username: '''admin''' (Software 01.06 and earlier: '''ADMIN''')
 
* Password: '''alphaadmin''' (Software 01.06 and earlier: '''alphacom''')
 
  
 
[[Category: INCA - Restore Factory Defaults and Software Upgrade]]
 
[[Category: INCA - Restore Factory Defaults and Software Upgrade]]

Latest revision as of 13:25, 15 May 2018

APS.png

This procedure is applicable for:


The unit can be set to use either Static IP or DHCP. On the rear side of the PCB there is a red status LED. Pay attention to this LED during the restore procedure:

Connect a push button between pins 1 and 4

Procedure

  1. Connect a push button (KEY1) between pin 1 and 4 on the P4 connector.
  2. While pressing the button, power up the station kit and keep the button pressed.
  3. Release the button after exactly 2 flashes of the LED.
  4. Let the LED flash for exactly 2 more times (Static IP) or exactly 4 more times (DHCP), then press the button again.
  5. Keep the button pressed until the LED flashes fast 2 times (Static IP) or flashes fast 4 times (DHCP) indicating a successful reset.
  6. Release the button and the station will restart with the factory default settings.


Factory default values

  • Station Mode: Pulse
  • Station IP address: 169.254.1.100 or DHCP
  • Username: admin
  • Password: alphaadmin