Revision as of 10:03, 16 May 2013
The AlphaCom E exchanges has two serial ports. In AlphaCom E20 and E26 they are available on RJ45 connectors. In AlphaCom E7 the serial port 0 is on a 9 pin DSUB connector, and the serial port 1 is on a RJ45 connector.
The serial port 0 is RS232 only, the serial port 1 can be RS232, RS422 or RS485.
Pinout of the RJ45 connector:
RJ45 pinout | |
---|---|
RS232 | 3 = TX<br\>6 = RX<br\> 4&5 = GND |
RS422 | 1 = RX-<br\>2 = RX+<br\>7 = TX-<br\>8 = TX+ |
RS485 | 1/7 = Data - <br\> 2/8 = Data+ |
<br\><br\>
Adaptor cable from RJ-45 to 9-pin Female D-SUB:
RJ45 - AlphaCom E | 9 p Female DSUB |
---|---|
3 | 2 |
4&5 | 5 |
6 | 3 |
AlphaCom - RIO cabling
Cabling between the RIO unit and AlphaCom E using multidrop RS485:
AlphaCom RIO #1 RIO #n Serial 1 15 pin DSUB 15 pin DSUB RJ45 1 -----------------+-- 2 --+----------------+-- 2 | | | --- 4 --- --- 4 2 -----------------+-- 9 --+----------------+-- 9 | | | --- 11--- --- 11
In the 15 pin DSUB of the RIO unit pin 2 & 4 and 9 & 11 must be connected together.
Cabling between the RIO unit and AlphaCom XE using point to point RS232:
AlphaCom RIO Serial 1 9 pin DSUB RJ45 3 (TX) ---------------+-- 2 --+ 6 (RX) ---------------+-- 3 --+ 5 (GND) --------------+-- 5 --+