Difference between revisions of "IP-LCM Connections"
From Zenitel Wiki
(→Outputs) |
|||
Line 1: | Line 1: | ||
− | |||
[[File:IPLCM.png|thumb|500px|right]] | [[File:IPLCM.png|thumb|500px|right]] | ||
Line 18: | Line 17: | ||
== Indicators == | == Indicators == | ||
Each output has a LED which indicates if the output is active or not. | Each output has a LED which indicates if the output is active or not. | ||
+ | |||
+ | |||
+ | For information on the [[TKIS Connections|TKIS-2 kit connections, see this link]] |
Revision as of 09:22, 10 January 2019
Inputs
From the top left the inputs are numbered as pin 17 to pin 24. Each input has a corresponding input switch which toggles between closing contact and active input.
Outputs
From the left side the outputs are numbered as pin 17 to pin 24. Each output is a dual pole relay with normally open, normally close and common available on the pin header.
The bottom four outputs each has a corresponding switch. This allows forwarding power from the power forwarding connector to the relay normally open and common on each output.
Relay ratings:
- Outputs: DPDT (NO, NC, COM)
- Switched voltage: < 250VAC Rated (400VAC Max)
- Switched Voltage: < 2000 VA max
- Switching Current: < 8A rated (15A max, 4s)
Indicators
Each output has a LED which indicates if the output is active or not.
For information on the TKIS-2 kit connections, see this link