Difference between revisions of "SNMP in AlphaCom XE"
From Zenitel Wiki
Line 15: | Line 15: | ||
* rtp statistics (Audio Statistics) | * rtp statistics (Audio Statistics) | ||
− | All MIBS variables are accessed through SNMP | + | All MIBS variables are accessed through [SNMP#SNMPv2_and_Structure_of_Management_Information SNMP v2] protocol with community public. All variables are read only. |
− | |||
Example of reading the AlphaCom MIB with NET-SNMP: | Example of reading the AlphaCom MIB with NET-SNMP: | ||
− | > snmpwalk –v 2c –c public localhost enterprises.9362 | + | > snmpwalk –v 2c –c public localhost enterprises.9362 |
=== Where to get the MIB configuration file? === | === Where to get the MIB configuration file? === | ||
Line 25: | Line 24: | ||
See attached file | See attached file | ||
− | + | === How to activate SNMP in AC? === | |
− | === How to activate SNMP in AC? | ||
The default MIBS are always active, but you need to open the firewall in AlphaWeb (UDP port 161) | The default MIBS are always active, but you need to open the firewall in AlphaWeb (UDP port 161) | ||
Line 32: | Line 30: | ||
Select destination ‘SNMP Trap’ and configure which logs you want to send. | Select destination ‘SNMP Trap’ and configure which logs you want to send. | ||
The SNMP traps will be sent with the OID: enterprises.1000.1 (This may be subject to change since it is not using our own Zenitel SNMP OID) | The SNMP traps will be sent with the OID: enterprises.1000.1 (This may be subject to change since it is not using our own Zenitel SNMP OID) | ||
− | + | As a general rule it is better to use syslog directly for these kinds of log events and not SNMP. Most Building Management Systems handles both syslog and SNMP. The SNMP log options is implemented to serve systems that do not handle syslog.. | |
− | As a general rule | ||
− | |||
− | |||
− | |||
− | |||
− | |||
=== Witch function of SNMP in AC will be implemented in near future? === | === Witch function of SNMP in AC will be implemented in near future? === | ||
− | There is at this moment not any plans for more snmp implementation | + | There is at this moment not any plans for more snmp implementation. |
− | |||
− |
Revision as of 16:14, 23 May 2007
The AlphaCom E runs a SNMP service.
Zenitel Norway AS have assigned a Private Enterprise Number (OID): 26122
Contents
Frequently asked questions on the ACE SNMP implementation
Witch functions of SNMP are implemented?
In addition to the AlphaCom MIB, the standard MIBs mibII, ucd-snmp and snmpv2 are implemented. These Mibs only implements polled information.
The AlphaCom MIB implements two main statuses:
- amc status (Enabled/Disabled) (Same as AlphaWeb Node State/Operational)
- rtp statistics (Audio Statistics)
All MIBS variables are accessed through [SNMP#SNMPv2_and_Structure_of_Management_Information SNMP v2] protocol with community public. All variables are read only. Example of reading the AlphaCom MIB with NET-SNMP:
> snmpwalk –v 2c –c public localhost enterprises.9362
Where to get the MIB configuration file?
See attached file
How to activate SNMP in AC?
The default MIBS are always active, but you need to open the firewall in AlphaWeb (UDP port 161) If you need to log to snmp (snmp traps) it is possible to configure this in AlphaWeb ‘System Configuration’ / ‘Logging’ Select destination ‘SNMP Trap’ and configure which logs you want to send. The SNMP traps will be sent with the OID: enterprises.1000.1 (This may be subject to change since it is not using our own Zenitel SNMP OID) As a general rule it is better to use syslog directly for these kinds of log events and not SNMP. Most Building Management Systems handles both syslog and SNMP. The SNMP log options is implemented to serve systems that do not handle syslog..
Witch function of SNMP in AC will be implemented in near future?
There is at this moment not any plans for more snmp implementation.