INCA Display Station Restore Factory Defaults: Difference between revisions
From Zenitel Wiki
No edit summary |
No edit summary |
||
| (23 intermediate revisions by 3 users not shown) | |||
| Line 1: | Line 1: | ||
This procedure is the recommended procedure for all IP Stations with Display | {{AEIPS}}This procedure is the recommended procedure for all IP Stations with Display. | ||
The Station Menu is only available when the IP Station is | * The Station Menu is available in both Edge, Pulse and SIP mode. <br/> | ||
* In Alphacom mode the Station Menu is only available when the IP Station is offline mode. i.e. not registered to the server. | |||
'''See video:''' | |||
<div style="text-align:left;"> <youtube width="300" height="180">78K-S-pn5zg</youtube> </div> | |||
<br><br> | |||
==Procedure == | |||
* Press the '''Setup''' button beneath the display | * Press the '''Setup''' button beneath the display | ||
* Enter the password '''1851''' and press the '''Ok''' button. | * Enter the password '''1851''' and press the '''Ok''' button. | ||
| Line 13: | Line 18: | ||
|} | |} | ||
The station will now restart with factory settings. | == Factory default values == | ||
The station will now restart with factory settings: | |||
*Station Mode: '''Pulse''' | |||
*Station IP address: '''169.254.1.100''' | |||
*Username: '''admin''' | |||
*Password: '''alphaadmin''' | |||
{{note|This procedure may also be applied to the [[IP Master Station Kit - 1008093000]] if a Display is connected.}} | |||
[[Category: INCA - Restore Factory Defaults and Software Upgrade]] | [[Category: INCA - Restore Factory Defaults and Software Upgrade]] | ||
Latest revision as of 07:35, 24 October 2019
This procedure is the recommended procedure for all IP Stations with Display.
- The Station Menu is available in both Edge, Pulse and SIP mode.
- In Alphacom mode the Station Menu is only available when the IP Station is offline mode. i.e. not registered to the server.
See video:
Procedure
- Press the Setup button beneath the display
- Enter the password 1851 and press the Ok button.
- Navigate to Load defaults and press the Sel button.
- Press the Sel button to load factory defaults.
Factory default values
The station will now restart with factory settings:
- Station Mode: Pulse
- Station IP address: 169.254.1.100
- Username: admin
- Password: alphaadmin
| This procedure may also be applied to the IP Master Station Kit - 1008093000 if a Display is connected. |