Difference between revisions of "INCA Display Station Restore Factory Defaults"
From Zenitel Wiki
(7 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
− | {{ | + | {{AEIPS}}This procedure is the recommended procedure for all IP Stations with Display. |
− | The Station Menu is available when the IP Station is | + | * The Station Menu is available in both Edge, Pulse and SIP mode. <br/> |
+ | * In Alphacom mode the Station Menu is only available when the IP Station is offline mode. i.e. not registered to the server. | ||
'''See video:''' | '''See video:''' | ||
Line 7: | Line 8: | ||
<br><br> | <br><br> | ||
− | + | ==Procedure == | |
* Press the '''Setup''' button beneath the display | * Press the '''Setup''' button beneath the display | ||
* Enter the password '''1851''' and press the '''Ok''' button. | * Enter the password '''1851''' and press the '''Ok''' button. | ||
Line 17: | Line 18: | ||
|} | |} | ||
+ | == Factory default values == | ||
The station will now restart with factory settings: | The station will now restart with factory settings: | ||
*Station Mode: '''Pulse''' | *Station Mode: '''Pulse''' |
Latest revision as of 07:35, 24 October 2019
This procedure is the recommended procedure for all IP Stations with Display.
- The Station Menu is available in both Edge, Pulse and SIP mode.
- In Alphacom mode the Station Menu is only available when the IP Station is offline mode. i.e. not registered to the server.
See video:
Procedure
- Press the Setup button beneath the display
- Enter the password 1851 and press the Ok button.
- Navigate to Load defaults and press the Sel button.
- Press the Sel button to load factory defaults.
Factory default values
The station will now restart with factory settings:
- Station Mode: Pulse
- Station IP address: 169.254.1.100
- Username: admin
- Password: alphaadmin
This procedure may also be applied to the IP Master Station Kit - 1008093000 if a Display is connected. |