Flowire: Difference between revisions
From Zenitel Wiki
No edit summary |
mNo edit summary |
||
| Line 4: | Line 4: | ||
There are two variants: | There are two variants: | ||
* [[FCDC-1]] (1008080110 ) - Forwards power to the spare pairs of the Ethernet port | |||
* [[FCDC-2]] (1008080210) - Does not forward power to the Ethernet port | *[[FCDC-1]] (1008080110 ) - Forwards power to the spare pairs of the Ethernet port | ||
{{note|The FCDC-1 is directly forwarding the power from the Power Supply Unit to the Ethernet port. It is '''not''' using [[PoE]] (Power over Ethernet) technology}} | *[[FCDC-2]] (1008080210) - Does not forward power to the Ethernet port | ||
== Factory defaults == | {{note|The FCDC-1 is directly forwarding the power from the Power Supply Unit to the Ethernet port (802.3af Type 1 mode B only). This means it is using the spare pairs only for power, and there is no auto-sensing of polarity or load. It is '''not''' using [[PoE]] (Power over Ethernet) technology}} | ||
* Static IP address : '''169.254.1.10''' | ==Factory defaults== | ||
* DHCP enabled. If the unit obtains a dynamic IP address, it comes in addition to the static address. | |||
* NMK Password: '''HomePlugAV0123''' | *Static IP address : '''169.254.1.10''' | ||
*DHCP enabled. If the unit obtains a dynamic IP address, it comes in addition to the static address. | |||
*NMK Password: '''HomePlugAV0123''' | |||
MAC address range: 00:13:CB:0A:00:00 -> 00:13:CB:0A:80:00 | MAC address range: 00:13:CB:0A:00:00 -> 00:13:CB:0A:80:00 | ||
| Line 16: | Line 18: | ||
<br><br> | <br><br> | ||
== Reset to Factory defaults == | ==Reset to Factory defaults== | ||
Flowire can be reset to Factory defaults by pressing the button for 15 seconds. The recessed button is located next to the Ethernet connector. | Flowire can be reset to Factory defaults by pressing the button for 15 seconds. The recessed button is located next to the Ethernet connector. | ||
<br><br> | <br><br> | ||
== Related Information == | ==Related Information== | ||
*[https://www.zenitel.com/product/fcdc2 Additional Documentation on Zenitel.com] | |||
[[Category: Flowire]] | [[Category: Flowire]] | ||
Revision as of 10:37, 23 December 2019
Flowire is based on the HomePlug AV power line communications specification, only using 24 - 48 V DC as the medium. It is a network bridge between Ethernet and a PLC link.
There are two variants:
- FCDC-1 (1008080110 ) - Forwards power to the spare pairs of the Ethernet port
- FCDC-2 (1008080210) - Does not forward power to the Ethernet port
| The FCDC-1 is directly forwarding the power from the Power Supply Unit to the Ethernet port (802.3af Type 1 mode B only). This means it is using the spare pairs only for power, and there is no auto-sensing of polarity or load. It is not using PoE (Power over Ethernet) technology |
Factory defaults
- Static IP address : 169.254.1.10
- DHCP enabled. If the unit obtains a dynamic IP address, it comes in addition to the static address.
- NMK Password: HomePlugAV0123
MAC address range: 00:13:CB:0A:00:00 -> 00:13:CB:0A:80:00
Reset to Factory defaults
Flowire can be reset to Factory defaults by pressing the button for 15 seconds. The recessed button is located next to the Ethernet connector.