Difference between revisions of "Flowire"
From Zenitel Wiki
m (Tag: Visual edit) |
|||
Line 3: | Line 3: | ||
Flowire is based on the [https://en.wikipedia.org/wiki/HomePlug#HomePlug_AV HomePlug AV] power line communications specification, only using 24 - 48 V DC as the medium. It is a network bridge between Ethernet and a PLC link. | Flowire is based on the [https://en.wikipedia.org/wiki/HomePlug#HomePlug_AV HomePlug AV] power line communications specification, only using 24 - 48 V DC as the medium. It is a network bridge between Ethernet and a PLC link. | ||
− | There are | + | There are three variants: |
+ | *[[FCDC-3]] (1008080110 ) | ||
+ | The versions | ||
*[[FCDC-1]] (1008080110 ) - Forwards power to the spare pairs of the Ethernet port | *[[FCDC-1]] (1008080110 ) - Forwards power to the spare pairs of the Ethernet port | ||
*[[FCDC-2]] (1008080210) - Does not forward power to the Ethernet port | *[[FCDC-2]] (1008080210) - Does not forward power to the Ethernet port | ||
Line 13: | Line 15: | ||
*DHCP enabled. If the unit obtains a dynamic IP address, it comes in addition to the static address. | *DHCP enabled. If the unit obtains a dynamic IP address, it comes in addition to the static address. | ||
*NMK Password: '''HomePlugAV0123''' | *NMK Password: '''HomePlugAV0123''' | ||
− | |||
− | |||
<br><br> | <br><br> |
Revision as of 08:11, 31 January 2020
Flowire is based on the HomePlug AV power line communications specification, only using 24 - 48 V DC as the medium. It is a network bridge between Ethernet and a PLC link.
There are three variants:
- FCDC-3 (1008080110 )
The versions
- FCDC-1 (1008080110 ) - Forwards power to the spare pairs of the Ethernet port
- FCDC-2 (1008080210) - Does not forward power to the Ethernet port
The FCDC-1 is directly forwarding the power from the Power Supply Unit to the Ethernet port (802.3af Type 1 mode B only). This means it is using the spare pairs only for power, and there is no auto-sensing of polarity or load. It is not using PoE (Power over Ethernet) technology |
Factory defaults
- Static IP address : 169.254.1.10
- DHCP enabled. If the unit obtains a dynamic IP address, it comes in addition to the static address.
- NMK Password: HomePlugAV0123
Reset to Factory defaults
Flowire can be reset to Factory defaults by pressing the button for 15 seconds. The recessed button is located next to the Ethernet connector.