Difference between revisions of "INCA DualDisplay Station LED Indicators"
From Zenitel Wiki
Line 3: | Line 3: | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
'''Blinking at 1 second intervals:'''<br/> | '''Blinking at 1 second intervals:'''<br/> | ||
− | Station has no connection to the AlphaCom | + | Station has no connection to the ICX-AlphaCom Server. |
Possible reasons: | Possible reasons: | ||
Line 9: | Line 9: | ||
* Wrong AlphaCom IP address configured | * Wrong AlphaCom IP address configured | ||
* Invalid IP address | * Invalid IP address | ||
− | * No gateway or wrong gateway to the AlphaCom | + | * No gateway or wrong gateway to the ICX-AlphaCom Server |
'''Blinking at 5 second intervals:'''<br/> | '''Blinking at 5 second intervals:'''<br/> | ||
− | Station connected but NOT registered in the AlphaCom | + | Station connected but NOT registered in the ICX-AlphaCom Server. |
Possible reasons: | Possible reasons: | ||
* Station has not been programmed in AlphaPro | * Station has not been programmed in AlphaPro | ||
− | * Missing IP Station license in AlphaCom | + | * Missing IP Station license in ICX-AlphaCom Server |
'''No blinking:''' | '''No blinking:''' | ||
Possible reasons: | Possible reasons: | ||
− | * Station connected and registered to the AlphaCom | + | * Station connected and registered to the ICX-AlphaCom Server |
* Station not powered up (if no other LEDs are active) | * Station not powered up (if no other LEDs are active) | ||
[[Category:Station Indication LEDs]] | [[Category:Station Indication LEDs]] |
Revision as of 08:15, 20 November 2020
Station LED
Blinking at 1 second intervals:
Station has no connection to the ICX-AlphaCom Server.
Possible reasons:
- No connection to Ethernet
- Wrong AlphaCom IP address configured
- Invalid IP address
- No gateway or wrong gateway to the ICX-AlphaCom Server
Blinking at 5 second intervals:
Station connected but NOT registered in the ICX-AlphaCom Server.
Possible reasons:
- Station has not been programmed in AlphaPro
- Missing IP Station license in ICX-AlphaCom Server
No blinking:
Possible reasons:
- Station connected and registered to the ICX-AlphaCom Server
- Station not powered up (if no other LEDs are active)