Actions

Difference between revisions of "IP Desktop Station LED Indications"

From Zenitel Wiki

 
Line 23: Line 23:
  
 
'''Blinking at 5 second intervals:'''<br/>
 
'''Blinking at 5 second intervals:'''<br/>
{{Note| This LED behaviour only applies to INCA Desktop stations [[IP Desktop Master Station - 1008000000|1008000000]], [[IP Desktop Master Station - 1008001000|1008001000]] and [[IP Desktop Station with Video Display - 1408001635|1208001635]]}}
+
{{Note| This LED behaviour only applies to INCA Desktop stations [[IP Desktop Master Station - 1008000000|1008000000]] and [[IP OR Master Station - 1008015000|1008015000]] in ICX-AlphaCom mode}}
 
Station connected but NOT registered in the ICX-AlphaCom  
 
Station connected but NOT registered in the ICX-AlphaCom  
  

Latest revision as of 11:10, 20 November 2020

Station LED

LED4 - Red 5mm LED on board rear side, also seen through front plate.

Station LED


Blinking at 1 second intervals:
Station cannot register to the server/controller

Possible reasons:

  • Invalid network settings (IP address and network mask) in the device
  • Wrong or missing account settings (Server IP, directory number, password..)
  • Failing to register due to missing license in the server
  • The server is offline
  • Network or Server firewall is not blocking port 50001 (ICX-AlphaCom) or 5060 (Edge/SIP)

If the server is on a different subnet, check that

  • A valid Default gateway is defined

No blinking:

Possible reasons:

  • Station connected and registered to the ICX-AlphaCom
  • Station not powered up (if no other LEDs are active)


Blinking at 5 second intervals:

Note icon This LED behaviour only applies to INCA Desktop stations 1008000000 and 1008015000 in ICX-AlphaCom mode


Station connected but NOT registered in the ICX-AlphaCom

Possible reasons:

  • Station has not been programmed in AlphaPro
  • Missing IP Station license in the ICX-AlphaCom