Actions

Difference between revisions of "1-3b. IP Stations – Substations (solution)"

From Zenitel Wiki

(Configure the IP Substation)
(Related articles)
 
(One intermediate revision by one other user not shown)
Line 18: Line 18:
 
* On the PC start a web browser, and enter the IP station address 169.254.1.100 in the address field
 
* On the PC start a web browser, and enter the IP station address 169.254.1.100 in the address field
 
* Log in with Username: '''admin''', password: '''alphaadmin'''
 
* Log in with Username: '''admin''', password: '''alphaadmin'''
* Select '''CCoIP Configuration''', and enter the following parameters:
+
* Select '''Station Main''' -> '''Main Settings''', and enter the following parameters:
[[File:1-3b solution2.PNG|thumb|left|400px|Enter the IP settings in the IP Station web page]]
+
[[File:1-3b solution2.PNG|thumb|left|500px|Enter the IP settings in the IP Station web page]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
 
* Connect the IP substation and the AlphaCom XE (Eth1) to the same network switch
 
* Connect the IP substation and the AlphaCom XE (Eth1) to the same network switch
Line 51: Line 51:
 
===Related articles ===
 
===Related articles ===
 
* [[1-3b. IP Stations – Substations (practice)]]
 
* [[1-3b. IP Stations – Substations (practice)]]
 +
 +
[[Category: AlphaCom practice]]

Latest revision as of 10:04, 30 June 2022

System configuration



Station configuration

Configure the IP Substation

  • Perform a "Factory Default" setting on the IP Substation:
    • Press the call button
    • While the button is pressed, connect the IP Substation to the PoE switch
    • Wait until the call LED of the station has flashed two times
    • Release the call button and wait for two new flashes
    • Push the button briefly after the two flashes
  • Assign the PC an IP address in the range 169.254.x.x
  • Connect the PC to the network switch
Accessing the IP Substations web page


  • On the PC start a web browser, and enter the IP station address 169.254.1.100 in the address field
  • Log in with Username: admin, password: alphaadmin
  • Select Station Main -> Main Settings, and enter the following parameters:
Enter the IP settings in the IP Station web page


  • Connect the IP substation and the AlphaCom XE (Eth1) to the same network switch

Configure the AlphaCom XE

  • In AlphaPro go to Users & Stations, and select physical number 39; 139 Station 39
  • Use the section on the right and change the configuration as follows:
AlphaPro: Users & Stations window


Call Button

  • In AlphaPro, Users & Stations, select physical port 39. Then press the button DAK, and configure as follows:
AlphaPro: Users & Stations -> DAK window



  • Send the changes to the AlphaCom XE

SendChg.PNG

Troubleshooting

  • If the IP station does not register, check the following:
    • In AlphaWeb, System Configuration -> Filters, verify that port for IP Stations and VoIP Audio is enabled
    • In AlphaWeb, System Configuration -> Licenses, verify that there are licenses installed for the IP stations







Related articles