Actions

Difference between revisions of "1-4g. Main Features - Alarm Message Distribution (solution)"

From Zenitel Wiki

(Related articles)
 
(8 intermediate revisions by one other user not shown)
Line 4: Line 4:
 
'''Alarm Message Distribution (761)'''
 
'''Alarm Message Distribution (761)'''
 
* ''Upload the standard english ASVP package to the AlphaCom:''
 
* ''Upload the standard english ASVP package to the AlphaCom:''
 +
[[File:1-4g solution1.PNG|left|thumb|500px|From AlphaWeb, '''System Maintenance''' -> '''System Upgrade''', '''Browse''' to the file ''asvp_en_06.00.apkg'', then select '''Upload''' and then '''Install''']]
 +
<br style="clear:both;" />
  
* ''By pressing a DAK key on the Main Guard, the prerecorded alarm message (8191) should be distributed to all stations (84):''
 
  
 +
* ''By pressing a DAK key on the Main Guard, the prerecorded alarm message (8191) should be distributed to all stations (84)''
 
* ''Another DAK key should stop the message:''
 
* ''Another DAK key should stop the message:''
 +
[[File:1-4g solution2.PNG|left|thumb|500px|In AlphaPro, Users & Stations -> DAK, program two DAK keys to 761 + Group + Alarm message]]
 +
<br style="clear:both;" />
 +
 +
'''NOTE:''' the 761 code is by default available only for SuperUser station (COS 16). Make the function code valid also for stations in COS 1:
 +
[[File:1-4g solution4.PNG|left|thumb|500px|In AlphaPro, Class Of Service, make the code 761 (feature 68) valid]]
 +
<br style="clear:both;" />
 +
  
 
* ''Instead of using the standard alarm message, a new customized message available as wav file should be used:''
 
* ''Instead of using the standard alarm message, a new customized message available as wav file should be used:''
 +
[[File:1-4g solution3.PNG|left|thumb|500px|From AlphaWeb, '''System Configuration''' -> '''Messaging''', select''' Message Group''' 30 and '''Group Index''' 1, then '''Browse''' to the wav file and '''Upload''']]
 +
<br style="clear:both;" />
 +
  
 
* ''Instead of using the wav file, a new customized message should be recorded from a station:''
 
* ''Instead of using the wav file, a new customized message should be recorded from a station:''
 
+
On a SuperUser station, dial 8180 + 8191 + M to record.
  
 
<br><br><br><br>
 
<br><br><br><br>
Line 20: Line 32:
 
===Related articles ===
 
===Related articles ===
 
* [[1-4g. Main Features - Alarm Message Distribution (practice)]]
 
* [[1-4g. Main Features - Alarm Message Distribution (practice)]]
 +
 +
[[Category: AlphaCom practice]]

Latest revision as of 10:06, 30 June 2022

System configuration


Solution

Alarm Message Distribution (761)

  • Upload the standard english ASVP package to the AlphaCom:
From AlphaWeb, System Maintenance -> System Upgrade, Browse to the file asvp_en_06.00.apkg, then select Upload and then Install



  • By pressing a DAK key on the Main Guard, the prerecorded alarm message (8191) should be distributed to all stations (84)
  • Another DAK key should stop the message:
In AlphaPro, Users & Stations -> DAK, program two DAK keys to 761 + Group + Alarm message


NOTE: the 761 code is by default available only for SuperUser station (COS 16). Make the function code valid also for stations in COS 1:

In AlphaPro, Class Of Service, make the code 761 (feature 68) valid



  • Instead of using the standard alarm message, a new customized message available as wav file should be used:
From AlphaWeb, System Configuration -> Messaging, select Message Group 30 and Group Index 1, then Browse to the wav file and Upload



  • Instead of using the wav file, a new customized message should be recorded from a station:

On a SuperUser station, dial 8180 + 8191 + M to record.