Pulsing of RCO (Event Handler): Difference between revisions
From Zenitel Wiki
No edit summary |
No edit summary |
||
| (4 intermediate revisions by 2 users not shown) | |||
| Line 1: | Line 1: | ||
{{AI}} | |||
===Function required=== | ===Function required=== | ||
A selection of intercom stations should, by dialing a number on the keypad, or by pressing a DAK key, be able to pulse a relay for 5 seconds. | A selection of intercom stations should, by dialing a number on the keypad, or by pressing a DAK key, be able to pulse a relay for 5 seconds. | ||
| Line 8: | Line 9: | ||
Second, in [[AlphaPro]], go to [[Exchange_%26_System_%28AlphaPro%29#Events|Exchange and System -> Events]], press Insert and create the following event: | Second, in [[AlphaPro]], go to [[Exchange_%26_System_%28AlphaPro%29#Events|Exchange and System -> Events]], press Insert and create the following event: | ||
[[File:Application20.png|left|thumb|500px]] | |||
<br style="clear:both;" /> | |||
| | |||
{{Code2| | |||
RCO 3 ON 50 | |||
}} | |||
[[Category:Applications]] | |||
[[Category:AlphaCom Applications]] | |||
[[Category: ICX-AlphaCom Applications]] | |||
[[Category:Applications using Event Handler]] | |||
Latest revision as of 10:34, 8 July 2022
Function required
A selection of intercom stations should, by dialing a number on the keypad, or by pressing a DAK key, be able to pulse a relay for 5 seconds.
Solution
The stations dial an Event Trigger number (feature 85), say number 9533, to pulse the RCO 3 for 5 seconds.
First, assign the stations to UDP group 1.
Second, in AlphaPro, go to Exchange and System -> Events, press Insert and create the following event:
Action commands:
RCO 3 ON 50