This article describes how to increase the volume of | {{AI}} | ||
This article describes how to '''increase the volume of a group call''' announcement. The volume is set back to default value when the group call is ended. | |||
== Prerequisites == | |||
* This event is CPU extensive. Maximum members in a group using this feature '''should not exceed approx. 50 stations'''. (Not applicable for ICX-AlphaCom) | |||
* Minimum software: AMC version 11. | |||
In the following example | == Configuration == | ||
In the following example the volume will be set to level 6 when group call 86 is called from stations in [[UDP group]] 2. The volume is set to level 3 (default) when the group call is ended. | |||
When stations outside UDP group 2 dial group call 86 this event will not be triggered, and the volume will not be altered. | |||
In [[AlphaPro]], go to [[Exchange_%26_System_%28AlphaPro%29#Events|'''Exchange and System''' -> '''Events''']], press '''Insert''' and create the following event: | |||
[[File:Application14a.png|500px|left|thumb]] | |||
<br style="clear:both;" /> | |||
{{Code2| | |||
IF %chg(1,0) | |||
tmp 0 "%gns(3,0)" | |||
LOOP | |||
IF %op(%tmp(0),<nowiki>=</nowiki>,0) | |||
STOP | |||
ENDIF | |||
$VOL N%tmp(0) U6 | |||
tmp 0 "%gns(3, %tmp(0))" | |||
ENDLOOP | |||
STOP | |||
ENDIF | |||
tmp 0 "%gns(3,0)" | |||
LOOP | |||
IF %op(%tmp(0),<nowiki>=</nowiki>,0) | |||
STOP | |||
ENDIF | |||
$VOL N%tmp(0) U3 | |||
tmp 0 "%gns(3, %tmp(0))" | |||
ENDLOOP | |||
}} | |||
In the action strings above, there are two lines that defines the volume. Volume during group call is set to 6 (U6) by the command: | |||
{{Code|$VOL N%tmp(0) U6}} | |||
Volume is set to 3 (U3) when the group call is ended by the command: | |||
{{Code|$VOL N%tmp(0) U3}} | |||
| | |||
U6 and U3 can be changed to other values if required. | |||
In the | In %gns(3, %tmp(0)) in the example, the 3 stands for group 3 (86), and must be changed if a different group is used. | ||
Note that a standard feature exists, which might be a better alternative: | |||
Group calls with "[[Groups#Group_Call_Setup_Priority|Setup Priority = Alarm]]" will automatically use the [[Volume and handset override|Volume Override feature]] of the ICX-AlphaCom, without any additional configuration required. | |||
| | |||
[[Category:AlphaCom Applications]] | |||
- | [[Category:ICX-AlphaCom Applications]] | ||
[[Category:Applications using Event Handler]] | |||
[[Category:Applications]] | |||
Latest revision as of 14:22, 11 August 2022
This article describes how to increase the volume of a group call announcement. The volume is set back to default value when the group call is ended.
Prerequisites
- This event is CPU extensive. Maximum members in a group using this feature should not exceed approx. 50 stations. (Not applicable for ICX-AlphaCom)
- Minimum software: AMC version 11.
Configuration
In the following example the volume will be set to level 6 when group call 86 is called from stations in UDP group 2. The volume is set to level 3 (default) when the group call is ended.
When stations outside UDP group 2 dial group call 86 this event will not be triggered, and the volume will not be altered.
In AlphaPro, go to Exchange and System -> Events, press Insert and create the following event:
Action commands:
IF %chg(1,0) tmp 0 "%gns(3,0)" LOOP IF %op(%tmp(0),=,0) STOP ENDIF $VOL N%tmp(0) U6 tmp 0 "%gns(3, %tmp(0))" ENDLOOP STOP ENDIF tmp 0 "%gns(3,0)" LOOP IF %op(%tmp(0),=,0) STOP ENDIF $VOL N%tmp(0) U3 tmp 0 "%gns(3, %tmp(0))" ENDLOOP
In the action strings above, there are two lines that defines the volume. Volume during group call is set to 6 (U6) by the command:
$VOL N%tmp(0) U6
|
Volume is set to 3 (U3) when the group call is ended by the command:
$VOL N%tmp(0) U3
|
U6 and U3 can be changed to other values if required.
In %gns(3, %tmp(0)) in the example, the 3 stands for group 3 (86), and must be changed if a different group is used.
Note that a standard feature exists, which might be a better alternative: Group calls with "Setup Priority = Alarm" will automatically use the Volume Override feature of the ICX-AlphaCom, without any additional configuration required.