Difference between revisions of "Tamper switch"
From Zenitel Wiki
(→For all stations) |
|||
Line 9: | Line 9: | ||
<br style="clear:both;" /> | <br style="clear:both;" /> | ||
− | {{code2|$STM L110 L101 | + | {{code2|$STM L110 L101 U145 'TAMPER CELL 10'}} |
=== For all stations === | === For all stations === |
Revision as of 13:44, 1 December 2022
The IP Vandal Resistant Substation with TKIE has the possibility to be fitted with a tamper switch. Making it possible to raise an alarm if the station is dismounted from the backbox.
Contents
Configuration
For a single station
In AlphaPro, create this event for the Tamper Switch, setting the substation as the event owner:
Action commands:
$STM L110 L101 U145 'TAMPER CELL 10'
For all stations
In AlphaPro, create this event for the Tamper Switch, and configure UDP Group 8 as event owner:
Action commands:
$STM L%2.dir L101 U145 '%1.nam'
Verify that I/O 3 is set as an input
The IP Substation must have I/O number 3 defined as an input (default).
Mounting
Mounting instruction on Tamper Switch for IP Vandal Resistant Substation TKIE
Step 1: Remove the two nylon nuts shown below
Step 2: Attach the supplied spacers
Step 3: Mount the tamper switch board
Step 4: Move the button GND wire from the the TKIE board to the tamper switch board
Step 5: Use the supplied wires to connect GND and Input 3 as shown below