Actions

Difference between revisions of "Start Alarm message at station feature"

From Zenitel Wiki

 
(15 intermediate revisions by 3 users not shown)
Line 1: Line 1:
 +
{{AI}}
 
{|  
 
{|  
 
|-
 
|-
Line 10: Line 11:
 
|'''Parameter 1''': || 1-9 = Alarm message number. 0 = Alarm Off
 
|'''Parameter 1''': || 1-9 = Alarm message number. 0 = Alarm Off
 
|-valign="top"  
 
|-valign="top"  
|'''Description''': || Start playback of [[alarm message]] at own station by dialling the alarm number. The alarm message is switched off by dialling 8190. The feature require [[ASVP]] board.
+
|'''Description''': || Start playback of [[alarm message]] at own station by dialling the alarm number (8191 - 8199). The alarm message is switched off by dialling 8190. The feature requires [[ASVP]] board.
 +
<br>
 +
'''Additional information:'''
 +
*This feature is normally used together with the feature code 761 for [[Remote setup of Alarm message feature|Remote setup of Alarm message]].
  
These feature codes are normally used together with the feature code 761 for [[Remote setup of Alarm message feature|Remote setup of Alarm message]]
+
*Alarm messages can also be triggered from the [[Event Handler]] or [[RCI]] by using the commands [[AMS - Alarm Message to Station|AMS]] or [[AMG]], or the [[ACDP|AlphaCom Data Protocol]] command [[ALARM MSG|$ALRM]]
 +
 
 +
'''See also:'''
 +
* [[Add new ASVP alarm messages (MDF)]]
  
 
|}
 
|}

Latest revision as of 09:53, 5 May 2023

AI.png
Feature: Alarm Message to Station
Default directory number: 8190 - 8199
Feature number: 67
Parameter 1: 1-9 = Alarm message number. 0 = Alarm Off
Description: Start playback of alarm message at own station by dialling the alarm number (8191 - 8199). The alarm message is switched off by dialling 8190. The feature requires ASVP board.


Additional information:

See also:


Back to feature list