There are 6 I/O connection options for the IP Hotline Station.
 
There are 6 I/O connection options for the IP Hotline Station.
 
These connections can be used to interface with external I/O devices. The connections are typically used as digital input (eg. from a closing contact), digital output (5V), or LED driving (20mA max) for connecting sensors, indicators or integration to other systems.  
 
These connections can be used to interface with external I/O devices. The connections are typically used as digital input (eg. from a closing contact), digital output (5V), or LED driving (20mA max) for connecting sensors, indicators or integration to other systems.  
 
==== P2 - Relay Output and External Power Input ====
 
5-pin plug-on terminal for relay and external power
 
[[File:TCIS Connections 5.PNG|thumb|500px|left]]
 
<br style="clear:both;" />
 
:Pin 1/2:  24 VDC for external secondary power if PoE is not used. Pin 1 is positive.
 
:Pin 3: COM relay (Common)
 
:Pin 4: NO relay (Normally Open)
 
:Pin 5: NC relay (Normally Closed)
 
 
* Relay switching capacity: Max. 60 watt (Max voltage: 250VAC/220VDC. Max current: 2A)
 
* Connectable conductors:  0.20 - 1.5 mm² (IEC) / 24 - 16 AWG (UL). Use of ferrules is recommended. Max cable size is then 0.75 mm².
 
  
 
==== P3 - 10-pin plug-on terminal for I/O's and Audio Line Out ====
 
==== P3 - 10-pin plug-on terminal for I/O's and Audio Line Out ====

Revision as of 12:21, 23 June 2023

The IP Hotline comes with either the INCA IP Flush Master board, or the TKIS-2 kit inside.

Turbine Based

Introduction

1008070010 Hotline IP-TKIS.png


Input/Output Connections

There are 6 I/O connection options for the IP Hotline Station. These connections can be used to interface with external I/O devices. The connections are typically used as digital input (eg. from a closing contact), digital output (5V), or LED driving (20mA max) for connecting sensors, indicators or integration to other systems.

P3 - 10-pin plug-on terminal for I/O's and Audio Line Out

TCIS Connections 6.PNG
Pin 1 5.3V (max. 200mA current)
Pin 2 GND
Pin 3 Input for Hookswitch for handset cradle (and for restoring Factory Default Setting)
Pin 4 Button Input or LED Driver
Pin 5 Button Input or LED Driver
Pin 6 Button Input or LED Driver
Pin 7 Button Input or LED Driver
Pin 8 Button Input or LED Driver
Pin 9 600 ohm balanced line out +
Pin 10 600 ohm balanced line out -


  • Connectable conductors: 0.20 - 1.5 mm² (IEC) / 24 - 16 AWG (UL). Use of ferrules is recommended. Max cable size is then 0.75 mm².

P4 - Loudspeaker & Electret microphone

TCIS Connections 7.PNG


Pin 1: Speaker output +
Pin 2: Speaker output -
Pin 3: Electret Microphone +
Pin 4: Electret Microphone -
  • Connectable conductors: 0.20 - 1.5 mm² (IEC) / 24 - 16 AWG (UL). Use of ferrules is recommended. Max cable size is then 0.75 mm².
  • Recommended loudspeaker impedance: 8 ohms
Note icon To enable the electret microphone input when using a TKIS-2, the "Product Model And Accessory" must be set to "Kit" under Station Main > Main Settings in the web interface of the device.