The IP Hotline comes with either the INCA IP Flush Master board, or the TKIS-2 kit inside.
The IP Hotline handset is using the Mic and Speaker connectors for audio.
==Turbine Based==
=== Introduction ===
[[File:TKIS-2_2.png|right|300px]]
The table below is an overview of the main connectors involved when installing the IP Hotline Station.


{| border="1"
I/O #1 is used as an input to detect the hook switch
|Ethernet/Power|| 10/100 Mbps Ethernet RJ-45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
|-
|Secondary Power || 24 VDC (16 – 48 V) secondary power is provided from an external adapter.
|-
|Relays || There is one Double Throw relay contact with 60W switching power. COM, NO, NC contacts are provided. Max: 250VAC/220VDC, 2A, 60W
|-
|Input/Output || 6 general purpose I/Os are available. Each I/O can be configured as either input, output, or LED driver.
|-
|Audio Line Out || A balanced 600 ohm audio line out with induction loop signal
|}


To access these connectors the front cover must be removed.
For more details see [[Turbine Compact series board connectors]]


[[File:1008070010 Hotline IP-TKIS.png|500px]]


=== Power Supply ===
The IP Hotline Station supports Power over Ethernet (PoE, IEEE 802.3 a-f) where power can be drawn from either the spare line or signal line.
If PoE is not available, the IP Hotline Station  can be connected to a 24 VDC local power supply.
See Related Article [[TKIS Connections]] for local power supply connections.
=== Network Connection ===
There is one RJ-45 port on this IP Hotline Station that is used for PoE/LAN Ethernet connection:
:* LAN port (P1): for connecting to the network and the AlphaCom XE Audio Server.
=== Input/Output Connections ===
There are 6 I/O connection options for the IP Hotline Station.
These connections can be used to interface with external I/O devices. The connections are typically used as digital input (eg. from a closing contact), digital output (5V), or LED driving (20mA max) for connecting sensors, indicators or integration to other systems.
==== P2 - Relay Output and External Power Input ====
[[File:IP Master Board 2.PNG|left|thumb|200px|P3]]
<br style="clear:both;" />
*Pin 1/2  Connection to the loudspeaker of the handset
*Pin 3/4  Internal NO relay contact for additional call indication etc.
*Pin 5/6  Connect 24 VDC for station power if PoE is not used. Pin 6 is positive.
==== P4 - Inputs and Station LED ====
6-pin plug-on screw terminal for external connections.
[[File:IP Master Board 3.PNG|left|thumb|200px|P4]]
<br style="clear:both;" />
*Pin 1/4  Input for Hookswitch for handset cradle (and for restoring Factory Default Setting)
*Pin 2/4  Input 2 (optional)
*Pin 3/4  Input 3 (optional)
*Pin 5/6  Station LED for call message info. (Pin 6 is positive.)
==== J10 - Microphone ====
Connection to handset microphone
[[File:IP Master Board 10.PNG|left|thumb|200px|J10]]
<br style="clear:both;" />
*Pin 1  MIC+
*Pin 2  MIC-
Note that the microphone selection switch next to connector J10 should be in the '''left position''', labeled "Int.".
For more details see [[INCA Substation Board Connectors]].
==INCA Based==
=== Introduction ===
The table below is an overview of the main connectors involved when installing the IP Hotline Station.
{| border="1"
|-
| align=left | LAN (P1) || 10/100 Mbps RJ45 port for LAN (uplink) connection. Supports PoE (802.3af). Draws power from either spare line or signal line.
|-
| align=left | AUX (P2) || 10/100 Mbps RJ45 port for auxilliary equipment such as PC or IP Camera.
|-
| align=left | Input/Output || Pluggable screw terminal
|-
| align=left | Local Power || Pluggable screw terminal, 17-27 VDC Idle 4W, max. 8W
|-
|}
To access these connectors the front cover must be removed.
[[File:IP Master Station Kit.PNG|right|300px]]
=== Power Supply ===
The IP Hotline Station supports Power over Ethernet (PoE, IEEE 802.3 a-f) where power can be drawn from either the spare line or signal line.
If PoE is not available, the IP Hotline Station  can be connected to a 24 VDC local power supply.
See Related Article [[INCA Master Station Kit Board Connectors]] for local power supply connections.
=== Network Connection ===
There are two RJ45 ports on this IP Hotline Station:
:* LAN port (P1): for connecting to the network and the AlphaCom XE Audio Server.
:* AUX port (P2): for connecting to auxiliary equipment such as a PC or IP Camera.
=== Input/Output Connections ===
There are I/O connection options for the IP Hotline Station. These I/O connections include:
==== P3 - External Loudspeaker, Relay Output and External Power Input ====
6-pin plug-on screw terminal for external connections.
[[File:IP Master Board 2.PNG|left|thumb|200px|P3]]
<br style="clear:both;" />
*Pin 1/2  Connection to the loudspeaker of the handset
*Pin 3/4  Internal NO relay contact for additional call indication etc.
*Pin 5/6  Connect 24 VDC for station power if PoE is not used. Pin 6 is positive.
==== P4 - Inputs and Station LED ====
6-pin plug-on screw terminal for external connections.
[[File:IP Master Board 3.PNG|left|thumb|200px|P4]]
<br style="clear:both;" />
*Pin 1/4  Input for Hookswitch for handset cradle (and for restoring Factory Default Setting)
*Pin 2/4  Input 2 (optional)
*Pin 3/4  Input 3 (optional)
*Pin 5/6  Station LED for call message info. (Pin 6 is positive.)
==== J10 - Microphone ====
Connection to handset microphone
[[File:IP Master Board 10.PNG|left|thumb|200px|J10]]
<br style="clear:both;" />
*Pin 1  MIC+
*Pin 2  MIC-
Note that the microphone selection switch next to connector J10 should be in the '''left position''', labeled "Int.".
For more details see [[INCA Substation Board Connectors]].
[[Category: INCA Connections]]
[[Category: Turbine Connections]]
[[Category: Turbine Connections]]

Latest revision as of 12:26, 23 June 2023

The IP Hotline handset is using the Mic and Speaker connectors for audio.

I/O #1 is used as an input to detect the hook switch

For more details see Turbine Compact series board connectors

1008070010 Hotline IP-TKIS.png

MediaWiki spam blocked by CleanTalk.