|
|
(5 intermediate revisions by the same user not shown) |
Line 1: |
Line 1: |
− | The IP Hotline comes with either the INCA IP Flush Master board, or the TKIS-2 kit inside. | + | The IP Hotline handset is using the Mic and Speaker connectors for audio. |
− | ==Turbine Based==
| |
− | === Introduction ===
| |
− | [[File:1008070010 Hotline IP-TKIS.png|right|300px]]
| |
| | | |
| + | I/O #1 is used as an input to detect the hook switch |
| | | |
− | === Input/Output Connections ===
| + | For more details see [[Turbine Compact series board connectors]] |
− | There are 6 I/O connection options for the IP Hotline Station.
| |
− | These connections can be used to interface with external I/O devices. The connections are typically used as digital input (eg. from a closing contact), digital output (5V), or LED driving (20mA max) for connecting sensors, indicators or integration to other systems.
| |
− | | |
− | ==== P3 - 10-pin plug-on terminal for I/O's and Audio Line Out ====
| |
− | [[File:TCIS Connections 6.PNG|thumb|300px|left]]
| |
− | | |
− | :Pin 1 5.3V (max. 200mA current)
| |
− | :Pin 2 GND
| |
− | :Pin 3 Input for Hookswitch for handset cradle (and for restoring Factory Default Setting)
| |
− | :Pin 4 Button Input or LED Driver
| |
− | :Pin 5 Button Input or LED Driver
| |
− | :Pin 6 Button Input or LED Driver
| |
− | :Pin 7 Button Input or LED Driver
| |
− | :Pin 8 Button Input or LED Driver
| |
− | :Pin 9 600 ohm balanced line out +
| |
− | :Pin 10 600 ohm balanced line out -
| |
− | | |
− | <br style="clear:both;" />
| |
− | * Connectable conductors: 0.20 - 1.5 mm² (IEC) / 24 - 16 AWG (UL). Use of ferrules is recommended. Max cable size is then 0.75 mm².
| |
− | | |
− | ==== P4 - Loudspeaker & Electret microphone ====
| |
− | [[File:TCIS Connections 7.PNG|thumb|500px|left]]
| |
− | <br style="clear:both;" />
| |
− | :Pin 1: Speaker output +
| |
− | :Pin 2: Speaker output -
| |
− | :Pin 3: Electret Microphone +
| |
− | :Pin 4: Electret Microphone -
| |
− | | |
− | * Connectable conductors: 0.20 - 1.5 mm² (IEC) / 24 - 16 AWG (UL). Use of ferrules is recommended. Max cable size is then 0.75 mm².
| |
− | * Recommended loudspeaker impedance: 8 ohms
| |
− | | |
− | {{Note | To enable the electret microphone input when using a [[TKIS-2]], the "'''Product Model And Accessory'''" must be set to "'''Kit'''" under [[Main Settings (IP Stations)|Station Main > Main Settings]] in the web interface of the device.}}
| |
− | | |
− | For more details see [[Turbine Compact Board Connectors]]. | |
| | | |
| + | [[File:1008070010 Hotline IP-TKIS.png|500px]] |
| | | |
| [[Category: Turbine Connections]] | | [[Category: Turbine Connections]] |