Difference between revisions of "External Data Input"
From Zenitel Wiki
(→Additional information) |
(→Additional information) |
||
Line 26: | Line 26: | ||
==Additional information== | ==Additional information== | ||
*Context parameters | *Context parameters | ||
− | :- [[ | + | :- [[%edi]] is the input text where termination character is excluded |
:- [[%sev]] is the EDI port (sub-event) | :- [[%sev]] is the EDI port (sub-event) | ||
Revision as of 09:38, 10 October 2023
The EDI ports are defined in AlphaPro: Exchange & System -> Serial Ports.
- The input message must have a termination character
- Maximum 128 characters. If longer strings, the first 128 characters will be returned, the rest will be ignored.
- Parsing the content is done in the action string in the Event Handler
Event description
Event Owner: | EDI Text Config |
Event type: | 28 - External Data Input |
Subevent: | 1 – 10: specifies which EDI port 0: matches all ports |
When change to ON: | When valid data is received on EDI port |
When change to OFF: | N/A |
When related to: | N/A |
Additional information
- Context parameters
- - [[%edi]] is the input text where termination character is excluded
- - %sev is the EDI port (sub-event)
- Useful macros and statements
- %scutc - Extract substring by byte (character) position
- %scutf - Extract field, fields defined by delimiter character
- %strlen - Return length of string
- %sscan - Scan for string, extract rest of string after first match
- %scmp - Compare strings
- TMP - Set temporary variable
- %tmp - Read temporary variable
The NUL character (ASCII 0x00) cannot be used in the EDI string. The processing of the string will be terminated when receiving NUL. |
Example
When receiving the text string "Start alarm 3", terminated by Line Feed character, play alarm message 3 (8193) to group 85: