Difference between revisions of "Temperature Alarm"
From Zenitel Wiki
(→Known problems with AMC hardware revision 8000/2) |
|||
(12 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
+ | {{A}} | ||
==Temperature alarm== | ==Temperature alarm== | ||
− | The AlphaCom monitors the temperature of the boards. If the temperature becomes too high, an internal [[RCI]] #8 is triggered, and the log event "Temperature Alarm" is generated: | + | The AlphaCom XE monitors the temperature of the boards. If the temperature becomes too high, an internal [[RCI]] #8 is triggered, and the log event "Temperature Alarm" is generated: |
Oct 10 12:54:35 src@Johnson AlphaLog: N001.D065:.Exch:ALARM 8 ON. | Oct 10 12:54:35 src@Johnson AlphaLog: N001.D065:.Exch:ALARM 8 ON. | ||
Oct 10 12:54:35 src@Johnson AlphaLog: N001.D065:.Exch:Temperature Alarm | Oct 10 12:54:35 src@Johnson AlphaLog: N001.D065:.Exch:Temperature Alarm | ||
− | In addition a mail is sent to station 1. The mail can be viewed by entering 70 and looks like this: | + | In addition a mail is sent to the station on [[physical number]] 1. The mail can be viewed by entering [[Stationreset feature|70 (Station reset)]] and looks like this: |
+ | |||
TemperatureAlarm | TemperatureAlarm | ||
0=Clear 8=Call | 0=Clear 8=Call | ||
− | == | + | |
+ | ==MultiModule== | ||
By default RCI 8 in the Master module is programmed to report Temperature Alarms. This needs to be done manually for the slaves. The RCI for the Master module is number 65/8. Slave 1 is 66/8, slave 2 is 67/8 and slave 3 is 68/8. | By default RCI 8 in the Master module is programmed to report Temperature Alarms. This needs to be done manually for the slaves. The RCI for the Master module is number 65/8. Slave 1 is 66/8, slave 2 is 67/8 and slave 3 is 68/8. | ||
− | ==Known problems with AMC hardware revision 8000/2== | + | |
+ | |||
+ | |||
+ | ==Known problems with AMC-IP hardware revision 8000/2== | ||
"Temperature Alarm" is reported when the AlphaCom E7 is powered ON: | "Temperature Alarm" is reported when the AlphaCom E7 is powered ON: | ||
− | * The hardware revision 8000/2 of the AMC-IP board has no support for the over-temperature signal from the ACE7 backplane. This is applicable for the E7 exchange only, and has been corrected in the 8002/4 hardware revision of the AMC-IP. | + | * The hardware revision 8000/2 of the AMC-IP board has no support for the over-temperature signal from the ACE7 backplane. This is applicable for the E7 exchange only, and has been corrected in the 8002/4 hardware revision of the AMC-IP. The hardware revision is printed on the rear side of the AMC-IP, top right corner. |
+ | * A workaround is to delete the ON and OFF action for RCI #8 to avoid "Temperature Alarm" to be reported to station #1 when powering on the AlphaCom E7. | ||
+ | [[File:Temp alarm.PNG|thumb|left|700px|Delete ON and OFF action if "Temperature Alarm" should not be reported to station #1]] | ||
− | [[Category:AlphaCom Troubleshooting]] | + | [[Category: AlphaCom Troubleshooting]] |
Latest revision as of 10:02, 8 February 2024
Temperature alarm
The AlphaCom XE monitors the temperature of the boards. If the temperature becomes too high, an internal RCI #8 is triggered, and the log event "Temperature Alarm" is generated:
Oct 10 12:54:35 src@Johnson AlphaLog: N001.D065:.Exch:ALARM 8 ON. Oct 10 12:54:35 src@Johnson AlphaLog: N001.D065:.Exch:Temperature Alarm
In addition a mail is sent to the station on physical number 1. The mail can be viewed by entering 70 (Station reset) and looks like this:
TemperatureAlarm 0=Clear 8=Call
MultiModule
By default RCI 8 in the Master module is programmed to report Temperature Alarms. This needs to be done manually for the slaves. The RCI for the Master module is number 65/8. Slave 1 is 66/8, slave 2 is 67/8 and slave 3 is 68/8.
Known problems with AMC-IP hardware revision 8000/2
"Temperature Alarm" is reported when the AlphaCom E7 is powered ON:
- The hardware revision 8000/2 of the AMC-IP board has no support for the over-temperature signal from the ACE7 backplane. This is applicable for the E7 exchange only, and has been corrected in the 8002/4 hardware revision of the AMC-IP. The hardware revision is printed on the rear side of the AMC-IP, top right corner.
- A workaround is to delete the ON and OFF action for RCI #8 to avoid "Temperature Alarm" to be reported to station #1 when powering on the AlphaCom E7.