Actions

Difference between revisions of "Turbine 9.0 - Release notes"

From Zenitel Wiki

 
(20 intermediate revisions by the same user not shown)
Line 1: Line 1:
 
* Previous Release - [[Turbine 8.2 - Release notes]]
 
* Previous Release - [[Turbine 8.2 - Release notes]]
  
This document provides the release notes for VSF-Turbine 8.0 with incremental bug fix releases. The release notes for VSF-Turbine 8.0 describe new features, improvements and issues fixed after VSF-Turbine 7.5.3.1.
+
This document provides the release notes for VSF-Turbine 9.0 with incremental bug fix releases. The release notes for VSF-Turbine 9.0 describe new features, improvements and issues fixed after VSF-Turbine 8.2.3.3.
 +
 
 +
VSF-Turbine (vsft) is a firmware archive for [[Zenitel Devices based on iMX28|Zenitel devices based on the IMX28 processor]].
  
 
==Release info==
 
==Release info==
Line 12: Line 14:
 
*vsft-prod-9.0.x.x - Used in production- and recovery upgrades
 
*vsft-prod-9.0.x.x - Used in production- and recovery upgrades
  
'''Version:''' vsft-9.0.3.0<br>
+
'''Version:''' vsft-9.0.3.1<br>
'''Date:''' xx.10.2024 <br>
+
'''Date:''' 22.10.2024 <br>
 
'''Status:''' General Availability
 
'''Status:''' General Availability
  
 +
=VSF-TURBINE 9.0.3.1=
 +
 +
==Fixed Issues==
 +
=== MTN-4590 Multicast relay sometimes had issues working with multicast paging===
 +
When devices were using SIP over UDP it could get multiple reinvites quickly that keep restarting media which in turn could mess up multicast paging on devices. As re-invites should not support media reconfiguration for multicast relay this is now disabled and paging works ok.
 +
 +
=== MTN-4572 AlphaCom Mixer station individual stream gain is not working===
 +
Now the 6 incoming RTP streams to mixer can again be individually gain controlled relative to the other streams.
 +
 +
=== MTN-4547 Fixed delay in triggering relay on TKIE-2===
 +
When triggering relay on TKIE-2 from another station, there was a delay in triggering relay on TKIE-2. This is now fixed.
 +
 +
=== MTN-4407 Removed Edge text on ENA2060===
 +
Edge mode is not supported on ENA2060 anymore, so label is removed now.
 +
 +
 +
<br>
 +
 +
==Known Issues==
 +
===MTN-4454 Multicast paging configuration is lost after upgrade to 8.2.3.0===
 +
As from 8.2.3.0, the multicast configuration in SIP and Edge mode is stored in a different format. Unfortunately, the configuration is lost after upgrade from a previous software version.
 +
 +
===MTN-4049 IP Heavy Duty Telephone shows speaker volume setting when in Edge Controller mode===
 +
IP Heavy Duty Telephones do not have a speaker, this has been disabled in the device model. The setting option in Edge Controller mode does not do anything and should be ignored
 +
 +
===MTN-3299 TLS Private Keys not restored on Turbine stations===
 +
In case that TLS Private Keys are deleted from Turbine station, the only way to restore them is to manually upload them to the station. Factory reset or station upgrade will not restore TLS Private Keys.
 +
 +
===MTN-2686 Outputs not working for Exigo amplifiers in SIP mode===
 +
GPO's does not work when exigo amplifiers are in SIP mode.
 +
 +
<br>
  
 
=VSF-TURBINE 9.0.3.0=
 
=VSF-TURBINE 9.0.3.0=
  
 
== Improvements==
 
== Improvements==
 +
=== MTN-4397 Improved certificate handling, and split SIP and HTTPS certificates into separate pages===
 +
Split SIP and HTTPS certificates into separate pages, removed turbine_server_sha1.key private key and TLS Private Key option, added factory reset handling, added backup and recovery for SIP certificates, fixed certificate regeneration on some devices, removed private keys from the device web page.
  
 +
=== MTN-3557 New configuration option for RTSP Audio Source===
 +
There’s a new option for configuring RTSP Audio Source, “Mixed signal”. This option mixes far and near end signal.
 +
 +
=== MTN-2936 Missing device report can be sent as SNMP trap===
 +
System controller can send missing device report or PSC down as SNMP trap.
 +
 +
=== SNMP trap, Missing Device===
 +
Added snmp trap "Missing Device" for ESC1.
 +
 +
=== DS-1034 Added support for codec L16x48 to Multicast Paging config===
 +
Devices can now listen to raw PCM 48 kHz audio stream (L16x48) when configured in HD-Audio mode.
 +
 +
=== DS-970 Added multicast relay feature===
 +
Device can now relay incoming RTP to specified address and port.
 +
 +
=== DS-889 Operate output when the call button is pressed in idle===
 +
Added option to configure operation of relays and outputs when the call button is pressed.
  
 
<br>
 
<br>
  
 
==Fixed Issues==
 
==Fixed Issues==
 +
=== MTN-4560 Setting L16x48 codec now added for ENA2060===
 +
There was no option to configure L16x48 codec, this is now fixed.
 +
 +
=== MTN-4546 Ringing and microphone input now heard if Pure Line-In signal active===
 +
When Pure Line-In signal option is active, and call was established, there was no switch to microphone input. This is now fixed.
 +
 +
=== MTN-4437 Fixed wrong device type shown when upgrading from version lower than 6.4===
 +
When upgrading EAPFX-1-V2 and EAPFX-6-V2 from version 6.4 or less to version higher than 7.0, wrong device type would be shown. This is now fixed.
 +
 +
=== MTN-4419 DAVC parameters for threshold are now applied===
 +
When upper threshold is lower than 80dBa in TFTP provisioning, the DAVC parameters for threshold were not applied
 +
 +
=== MTN-4382 VSFT devices can now be upgrade via SIP provisioning===
 +
The issue with software upgrade via SIP provisioning have been fixed
 +
 +
=== MTN-4365 ONVIF audio issues and potential reboot after 6-7 days of continuous streaming from devices using dummy video===
 +
There was an issue with integer overflow that caused cascading failures on system with non video ONVIF devices after 6-7 days. Failures included loss of audio in VMS, distorted audio and device reboots. Issue was present on all previous versions of non video ONVIF devices.
 +
 +
=== MTN-4349 Reboot issue on ECPIR-3P-C1 with gooseneck microphone selected when pressing PTT button is now fixed===
 +
The ECPIR-3P-C1 will no longer reboot itself after pressing the PTT button when gooseneck microphone is selected.
 +
 +
=== MTN-4252 ENA2x00-AC2 amplifiers could report faults during planned shutdown===
 +
Amplifiers could report “Low Voltage Alert” from internal voltage monitoring during shutdown of amplifier. Updated to not report this faults when it is due to shutdown of amplifier.
 +
 +
=== MTN-4251 Ground fault LED (Gnd) not indicating properly in case only Channel 1 has Ground fault===
 +
Ground fault LED updated to take into account faults on both channels and now indicating correctly under all circumstances.
 +
 +
=== MTN-4242 Speaker Line Monitoring (SLM) calibration and configuration data reset after power cycle===
 +
SLM calibration and configuration could get corrupted and reset if amplifier was powered off when configuration file was being written. Configuration file is now only written during calibration and on amplifier power up. Note: Changing Insulation resistance trigger lever from default 100k ohm is only provided for trained service personnel.
 +
 +
=== MTN-4090 Line fault LED takes long time to indicate for a detected fault===
 +
Line fault LED now reacts immediately when fault is detected.
 +
 +
=== MTN-4089 Amplifier reboots if manual Speaker Line Monitoring (SLM) measurements was done too early after power up===
 +
SLM parameters are now read immediately on application boot to avoid this behavior.
 +
 +
=== MTN-4066 ENA2x00-AC2: Improved speaker line monitoring (SLM) on long speaker lines===
 +
The speaker line monitoring (SLM) measurements on long speaker lines (technical perspective up to 800nF) have been improved.
 +
 +
=== MTN-3992 Improve filtering of SLM measurements on ENA2 AC2===
 +
Discard noisy SLM impedance measurements
 +
 +
=== MTN-3988 A failing LET can now be reported as a fault===
 +
Before the failing LET would always be reported as a warning independent on what was selected in EMT. This has now been fixed.
 +
 +
=== MTN-3987 ENA2x00-AC2: Adjustable ground fault limit===
 +
Detection limit can be set from terminal. Default is 100kohm.
 +
 +
=== MTN-3986 Fix ground fault measurement toggle===
 +
Ground fault measurement can be disabled
 +
 +
=== MTN-3982 ENA2x00-AC2: Removed occurrence of false ground fault detection===
 +
During calibration of systems with long speaker lines, detection of false ground fault could occur. This would again prevent the calibration of the speaker lines. The occurrence of false ground faults is no longer present.
 +
 +
=== MTN-3714 Improve SNMP daemon health detection===
 +
SNMP was restarting each 10 minutes due to error in checking its status
 +
 +
=== MTN-3637 SNMP Traps and MIB file update===
 +
Traps are and MIB file are updated to latest changes in vssnmp daemon
 +
 +
=== DS-1015 Permanent Audio Stream fixes and config refresh===
 +
Some parts of the audio stream config was not working correct and mic level was very low. Also linked to RTSP “Audio Source” config for impact which signal is sent to RTP stream.
 +
Consult wiki documentation for more details.
  
  
Line 30: Line 146:
  
 
==Known Issues==
 
==Known Issues==
 +
===MTN-4454 Multicast paging configuration is lost after upgrade to 8.2.3.0===
 +
As from 8.2.3.0, the multicast configuration in SIP and Edge mode is stored in a different format. Unfortunately, the configuration is lost after upgrade from a previous software version.
 +
 
===MTN-4049 IP Heavy Duty Telephone shows speaker volume setting when in Edge Controller mode===
 
===MTN-4049 IP Heavy Duty Telephone shows speaker volume setting when in Edge Controller mode===
 
IP Heavy Duty Telephones do not have a speaker, this has been disabled in the device model. The setting option in Edge Controller mode does not do anything and should be ignored
 
IP Heavy Duty Telephones do not have a speaker, this has been disabled in the device model. The setting option in Edge Controller mode does not do anything and should be ignored
 
===MTN-3489 Downgrading IP_LCM from vsft-6.4.3.0 will cause a reboot loop===
 
If downgrading the IP_LCM from vsft-6.4.3.0 to an earlier version, the IP_LCM will go into a reboot loop. Workaround is to factory reset the IP_LCM just after downgrading.
 
  
 
===MTN-3299 TLS Private Keys not restored on Turbine stations===  
 
===MTN-3299 TLS Private Keys not restored on Turbine stations===  
 
In case that TLS Private Keys are deleted from Turbine station, the only way to restore them is to manually upload them to the station. Factory reset or station upgrade will not restore TLS Private Keys.
 
In case that TLS Private Keys are deleted from Turbine station, the only way to restore them is to manually upload them to the station. Factory reset or station upgrade will not restore TLS Private Keys.
 
===MTN-2692 Turbine stations won't register to ICX500 or AlphaCom if the dash symbol is not removed from the Directory Number field.===
 
In an unconfigured Turbine station there is a dash character in the Directory Number field in the "Main Settings menu. This dash symbol must be removed when the directory number is entered, else the station will fail to register.
 
 
 
 
===MTN-2686 Outputs not working for Exigo amplifiers in SIP mode===  
 
===MTN-2686 Outputs not working for Exigo amplifiers in SIP mode===  
 
GPO's does not work when exigo amplifiers are in SIP mode.
 
GPO's does not work when exigo amplifiers are in SIP mode.
 
 
===MTN-2363 Factory reset does not delete uploaded Script===
+
 
All uploaded scripts should also be removed on Factory reset
 
 
===MTN-2362 H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream===
 
H.264 RTSP stream in UDP mode can display small artifacts at the bottom of the stream.
 
 
===MTN-2361 TCIV H264 stream does not work in Honeywell Maxpro NVR===
 
RTSP H.264 does not work in Honeywell Maxpro NVR, workaround is to use MJPEG RTSP stream
 
 
===MTN-2360 Client side forwarding does not work in SIP mode===
 
Client side forwarding, which can be configured as a DAK action or activated from INCA display menu, does not work in SIP mode. Workaround is to use SIP server side forwarding.
 
 
===MTN-2359 Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer===
 
Stream is not always established in Pelco VideoExpert VMS version 3.0 or newer, workaround is to follow all the steps described here https://wiki.zenitel.com/wiki/Adding_TCIV_ONVIF_camera_to_Pelco_VideoXpert_Professional when adding TCIV station to Pelco VideoExpert
 
 
===MTN-2358 Making a point-to-point call during High priority Group call will drop group call audio.===
 
When 2 stations establish a point-to-point call during High priority Group call, they will no longer receive audio from current High priority group call.
 
 
===MTN-2356 SNMP not working properly on TCIV under high CPU load===
 
SNMP is not working properly on TCIV under high CPU load, which means that SNMP traps and inform messages can be sent with delay, or not be sent at all. This only happens if TCIV is placed under very high load, under normal operating conditions SNMP function without any issues.
 
 
===MTN-2339 Group call chime is not played on 3rd party SIP stations===
 
Group call chime (WAV file) is not played on third party SIP devices when Group Call is set over multicast IP address.
 
 
===MTN-2220 Default SNMP settings issue with firmware downgrade to 4.9===
 
When downgrading from VSFT 4.11+ to 4.9 a factory reset is necessary if user wants to use default SNMP configuration. For custom snmp.conf file, re-upload with a custom snmp.conf file will fix the problem.
 
 
===MTN-1073 Group call fails if system previously configured with ZAP===
 
If system was configured with ZAP (VS-IMT Pulse SDK project) and then switched to XML configuration by deleting data.lua file, it is possible that Group Calls shall not work. A workaround is that (1) data.lua file is deleted from all stations including Pulse server - this will reboot stations, and (2) after reboot go to Server configuration -> Save + Apply - this will again reboot all stations.
 
  
  
  
 
[[Category: Release notes]]
 
[[Category: Release notes]]

Latest revision as of 07:42, 24 October 2024

This document provides the release notes for VSF-Turbine 9.0 with incremental bug fix releases. The release notes for VSF-Turbine 9.0 describe new features, improvements and issues fixed after VSF-Turbine 8.2.3.3.

VSF-Turbine (vsft) is a firmware archive for Zenitel devices based on the IMX28 processor.

Contents

Release info

Name: VSF-Turbine
Description: VSF-Turbine is a firmware archive for Zenitel devices based on the IMX28 processor.

The firmware is delivered in two different ZIP archives and one swu file:

  • vsft-9.0.x.x - Used for standard in-field upgrades
  • vsft-prod-9.0.x.x - Used in production- and recovery upgrades

Version: vsft-9.0.3.1
Date: 22.10.2024
Status: General Availability

VSF-TURBINE 9.0.3.1

Fixed Issues

MTN-4590 Multicast relay sometimes had issues working with multicast paging

When devices were using SIP over UDP it could get multiple reinvites quickly that keep restarting media which in turn could mess up multicast paging on devices. As re-invites should not support media reconfiguration for multicast relay this is now disabled and paging works ok.

MTN-4572 AlphaCom Mixer station individual stream gain is not working

Now the 6 incoming RTP streams to mixer can again be individually gain controlled relative to the other streams.

MTN-4547 Fixed delay in triggering relay on TKIE-2

When triggering relay on TKIE-2 from another station, there was a delay in triggering relay on TKIE-2. This is now fixed.

MTN-4407 Removed Edge text on ENA2060

Edge mode is not supported on ENA2060 anymore, so label is removed now.



Known Issues

MTN-4454 Multicast paging configuration is lost after upgrade to 8.2.3.0

As from 8.2.3.0, the multicast configuration in SIP and Edge mode is stored in a different format. Unfortunately, the configuration is lost after upgrade from a previous software version.

MTN-4049 IP Heavy Duty Telephone shows speaker volume setting when in Edge Controller mode

IP Heavy Duty Telephones do not have a speaker, this has been disabled in the device model. The setting option in Edge Controller mode does not do anything and should be ignored

MTN-3299 TLS Private Keys not restored on Turbine stations

In case that TLS Private Keys are deleted from Turbine station, the only way to restore them is to manually upload them to the station. Factory reset or station upgrade will not restore TLS Private Keys.

MTN-2686 Outputs not working for Exigo amplifiers in SIP mode

GPO's does not work when exigo amplifiers are in SIP mode.


VSF-TURBINE 9.0.3.0

Improvements

MTN-4397 Improved certificate handling, and split SIP and HTTPS certificates into separate pages

Split SIP and HTTPS certificates into separate pages, removed turbine_server_sha1.key private key and TLS Private Key option, added factory reset handling, added backup and recovery for SIP certificates, fixed certificate regeneration on some devices, removed private keys from the device web page.

MTN-3557 New configuration option for RTSP Audio Source

There’s a new option for configuring RTSP Audio Source, “Mixed signal”. This option mixes far and near end signal.

MTN-2936 Missing device report can be sent as SNMP trap

System controller can send missing device report or PSC down as SNMP trap.

SNMP trap, Missing Device

Added snmp trap "Missing Device" for ESC1.

DS-1034 Added support for codec L16x48 to Multicast Paging config

Devices can now listen to raw PCM 48 kHz audio stream (L16x48) when configured in HD-Audio mode.

DS-970 Added multicast relay feature

Device can now relay incoming RTP to specified address and port.

DS-889 Operate output when the call button is pressed in idle

Added option to configure operation of relays and outputs when the call button is pressed.


Fixed Issues

MTN-4560 Setting L16x48 codec now added for ENA2060

There was no option to configure L16x48 codec, this is now fixed.

MTN-4546 Ringing and microphone input now heard if Pure Line-In signal active

When Pure Line-In signal option is active, and call was established, there was no switch to microphone input. This is now fixed.

MTN-4437 Fixed wrong device type shown when upgrading from version lower than 6.4

When upgrading EAPFX-1-V2 and EAPFX-6-V2 from version 6.4 or less to version higher than 7.0, wrong device type would be shown. This is now fixed.

MTN-4419 DAVC parameters for threshold are now applied

When upper threshold is lower than 80dBa in TFTP provisioning, the DAVC parameters for threshold were not applied

MTN-4382 VSFT devices can now be upgrade via SIP provisioning

The issue with software upgrade via SIP provisioning have been fixed

MTN-4365 ONVIF audio issues and potential reboot after 6-7 days of continuous streaming from devices using dummy video

There was an issue with integer overflow that caused cascading failures on system with non video ONVIF devices after 6-7 days. Failures included loss of audio in VMS, distorted audio and device reboots. Issue was present on all previous versions of non video ONVIF devices.

MTN-4349 Reboot issue on ECPIR-3P-C1 with gooseneck microphone selected when pressing PTT button is now fixed

The ECPIR-3P-C1 will no longer reboot itself after pressing the PTT button when gooseneck microphone is selected.

MTN-4252 ENA2x00-AC2 amplifiers could report faults during planned shutdown

Amplifiers could report “Low Voltage Alert” from internal voltage monitoring during shutdown of amplifier. Updated to not report this faults when it is due to shutdown of amplifier.

MTN-4251 Ground fault LED (Gnd) not indicating properly in case only Channel 1 has Ground fault

Ground fault LED updated to take into account faults on both channels and now indicating correctly under all circumstances.

MTN-4242 Speaker Line Monitoring (SLM) calibration and configuration data reset after power cycle

SLM calibration and configuration could get corrupted and reset if amplifier was powered off when configuration file was being written. Configuration file is now only written during calibration and on amplifier power up. Note: Changing Insulation resistance trigger lever from default 100k ohm is only provided for trained service personnel.

MTN-4090 Line fault LED takes long time to indicate for a detected fault

Line fault LED now reacts immediately when fault is detected.

MTN-4089 Amplifier reboots if manual Speaker Line Monitoring (SLM) measurements was done too early after power up

SLM parameters are now read immediately on application boot to avoid this behavior.

MTN-4066 ENA2x00-AC2: Improved speaker line monitoring (SLM) on long speaker lines

The speaker line monitoring (SLM) measurements on long speaker lines (technical perspective up to 800nF) have been improved.

MTN-3992 Improve filtering of SLM measurements on ENA2 AC2

Discard noisy SLM impedance measurements

MTN-3988 A failing LET can now be reported as a fault

Before the failing LET would always be reported as a warning independent on what was selected in EMT. This has now been fixed.

MTN-3987 ENA2x00-AC2: Adjustable ground fault limit

Detection limit can be set from terminal. Default is 100kohm.

MTN-3986 Fix ground fault measurement toggle

Ground fault measurement can be disabled

MTN-3982 ENA2x00-AC2: Removed occurrence of false ground fault detection

During calibration of systems with long speaker lines, detection of false ground fault could occur. This would again prevent the calibration of the speaker lines. The occurrence of false ground faults is no longer present.

MTN-3714 Improve SNMP daemon health detection

SNMP was restarting each 10 minutes due to error in checking its status

MTN-3637 SNMP Traps and MIB file update

Traps are and MIB file are updated to latest changes in vssnmp daemon

DS-1015 Permanent Audio Stream fixes and config refresh

Some parts of the audio stream config was not working correct and mic level was very low. Also linked to RTSP “Audio Source” config for impact which signal is sent to RTP stream. Consult wiki documentation for more details.



Known Issues

MTN-4454 Multicast paging configuration is lost after upgrade to 8.2.3.0

As from 8.2.3.0, the multicast configuration in SIP and Edge mode is stored in a different format. Unfortunately, the configuration is lost after upgrade from a previous software version.

MTN-4049 IP Heavy Duty Telephone shows speaker volume setting when in Edge Controller mode

IP Heavy Duty Telephones do not have a speaker, this has been disabled in the device model. The setting option in Edge Controller mode does not do anything and should be ignored

MTN-3299 TLS Private Keys not restored on Turbine stations

In case that TLS Private Keys are deleted from Turbine station, the only way to restore them is to manually upload them to the station. Factory reset or station upgrade will not restore TLS Private Keys.

MTN-2686 Outputs not working for Exigo amplifiers in SIP mode

GPO's does not work when exigo amplifiers are in SIP mode.