Actions

ZIPS Restore Factory Defaults: Difference between revisions

From Zenitel Wiki

(Created page with "A Zenitel IP Speaker (ZIPS) may have to be reset to its original factory default settings if, for instance, the password to the station web interface is forgotten. The default...")
 
No edit summary
 
(2 intermediate revisions by 2 users not shown)
Line 1: Line 1:
A Zenitel IP Speaker (ZIPS) may have to be reset to its original factory default settings if, for instance, the password to the station web interface is forgotten. The defaults can either be set to Activated DHCP or Static IP.
A Zenitel IP Speaker (ZIPS) may have to be reset to its original factory default settings if, for instance, the password to the station web interface is forgotten. The defaults can either be set to Activated DHCP or Static IP.
Factory default settings can be [[Restore Factory Defaults - From the device web interface|restored from the web interface]], or by a hardware reset as explained below.
{{warn|USE EAR PROTECTION!!! Due to a bug the speaker will count at full power!
This bug is fixed from 9.1.3.0}}


__NOTOC__
__NOTOC__

Latest revision as of 14:07, 3 February 2025

A Zenitel IP Speaker (ZIPS) may have to be reset to its original factory default settings if, for instance, the password to the station web interface is forgotten. The defaults can either be set to Activated DHCP or Static IP.

Factory default settings can be restored from the web interface, or by a hardware reset as explained below.

Warning icon USE EAR PROTECTION!!! Due to a bug the speaker will count at full power!
This bug is fixed from 9.1.3.0



Preparation

  1. Connect a push button between the IO connector (pin 1) and Ground (pin 11)
ZIPSFactoryReset.png


Reset to Factory Default Settings with Activated DHCP

To reset:

  1. While pressing the button, power up the device by connecting to a PoE switch
  2. Hold the button until the device audio starts counting, and release the button on count 1
  3. Press and hold the button on count 5 and release on count 0
  • If there is no 0 count, the procedure has failed and you have to start again
  • Press the button, and the device will speak its IP address

Factory default values

Device IP address: Determined by DHCP server. If no DHCP server is available, it gets a random 169.254.x.x address.
Username: admin
Password: alphaadmin

Reset to Factory Default Settings with Static IP

To reset:

  1. While pressing the button, power up the device by connecting to a PoE switch
  2. Hold the button until the device audio starts counting, and release the button on count 1
  3. Press and hold the button on count 3 and release on count 0
  • If there is no 0 count, the procedure has failed and you have to start again
  • Press the button, and the device will speak its IP address

Factory default values

Device IP address: 169.254.1.100
Username: admin
Password: alphaadmin
MediaWiki spam blocked by CleanTalk.