Actions

Restore Factory Defaults - From the device web interface

From Zenitel Wiki

This article describes how to reset the device to factory default settings using the web interface of the device.

The Recovery page


  • Reboot system: Perform a full Linux reboot. No configuration is lost
  • Reboot main application: Perform a restart of the intercom application. No configuration is lost
  • Factory reset: Set all parameters to Factory Default values. The station will get static IP Address 169.254.1.100.
  • Factory reset with DHCP: Set all parameters to Factory Default values. The station will get IP Address from DHCP server. If no DHCP server in the network, it will get a random 169.254.x.x IP address.
  • Factory reset (Keep IP Settings): Set all parameters to Factory Default values. Keep the IP Settings. (From ver. 9.1.3.0.)
  • Clear local ZAP profile: For special purpose
  • Delete ZAP data.lua: For special purpose