* Check the AlphaCom XE1 software version. If the version is 11.x.x.x or older, the server should be upgraded to latest version | * Check the AlphaCom XE1 software version. If the version is 11.x.x.x or older, the server should be upgraded to latest version, see [[AMC-IP software upgrade (Black AMC-IP board)|upgrade procedure]]. | ||
* Make screenshots of AlphaWeb System Configuration pages: | * Make screenshots of AlphaWeb System Configuration pages: | ||
# Interfaces | # Interfaces | ||
Revision as of 13:54, 3 April 2025
This article describes best practice to replace an AlphaCom XE1 with an ICX-510 running AlphaCom software.
AlphaCom XE1
- Check the AlphaCom XE1 software version. If the version is 11.x.x.x or older, the server should be upgraded to latest version, see upgrade procedure.
- Make screenshots of AlphaWeb System Configuration pages:
- Interfaces
- Filters
- Routing
Optional:
- Time and Date
- Logging
- Messaging
- Use latest AlphaPro version and perform a Get All to backup the configuration.
ICX-AlphaCom
- Upgrade the ICX-AlphaCom to the latest software version
- Log in to the ICX-510 web-interface and configure according to the screenshots made of the AlphaCom XE1
- Upload audio messages if any
- Upload license file
- From AlphaPro connect to the ICX-510 and restore the configuration by doing a Send All