Actions

Difference between revisions of "STATUS REPORT"

From Zenitel Wiki

Line 25: Line 25:
 
|align=center|8||[[NET_OBJ_REF]]<br\>(optional)||colspan="3"|Entity Information field 1.<br\>.
 
|align=center|8||[[NET_OBJ_REF]]<br\>(optional)||colspan="3"|Entity Information field 1.<br\>.
 
|-
 
|-
|colspan="5"|'''STTUS_REP for Stat'''
+
|colspan="5"|'''STATUS_REPORT for Stations:'''
 
|-
 
|-
|align=center|1||NET_OBJ_REF||colspan="3"|Station from 1 to 552.<br\>The Sub Class field specifies the type of station interface (TouchLine, Telephone).<br\>Status info. can have different meaning for each Sub Class.
+
|align=center|1||[[NET_OBJ_REF]]||colspan="3"|Station from 1 to 552.<br\>The Sub Class field specifies the type of station interface (TouchLine, Telephone).<br\>Status info. can have different meaning for each Sub Class.
 
|-
 
|-
|align=center|2||NET_OBJ:REF||colspan="3"|Physical address:  Module/board/port.<br\>The (Implicit Type) Resource Address format is used
+
|align=center|2||[[NET_OBJ_REF]]||colspan="3"|Physical address:  Module/board/port.<br\>The (Implicit Type) Resource Address format is used
 
|-
 
|-
|align=center|3||BITMAP[1..8]||(Error) State Flags.<br\>Bit 1 = Interface present:<br\>Bit 2 = Interface test:<br\>Bit 6 = Audio test:<br\>Bit 7 = Device dep. test:||---What is reported for Stations:---<br\>ASLT/ATLB board missing <br\>ASLT/ATLB wire monitoring<br\>Tone Test <br\>Handset Off-Hook timeout ||(no active report)<br\>(only failures)<br\>(only changes)<br\>(only failures)
+
|align=center|3||[[BITMAP]][1..8]||(Error) State Flags.<br\>Bit 1 = Interface present:<br\>Bit 2 = Interface test:<br\>Bit 6 = Audio test:<br\>Bit 7 = Device dep. test:||---What is reported for Stations:---<br\>[[ASLT]]/[[ATLB]] board missing <br\>[[ASLT]]/[[ATLB]] wire monitoring<br\>Tone Test <br\>Handset Off-Hook timeout ||(no active report)<br\>(only failures)<br\>(only changes)<br\>(only failures)
 
|-
 
|-
|align=center|5||
+
|align=center|5||[[BITMAP]][1..8]||Reporting Flags.<br\>Bit 8 = [[VERBOSE]].||colspan="2"|&nbsp;<br\>Set by Tone Test started from station.
 
|-
 
|-
|colspan="2"|Response:
+
|align=center|6||[[UINT1]]||Status information 1.||colspan="2"|Bits describing ab- and cd- wire errors
|colspan="3"|COMMAND_RESPONSE
+
|-
 +
|align=center|7||[[UINT1]]||Status information 2.||colspan"2"|TouchLine: Tone test signal/noise value.<br\>Telephone: Wire monitor current.
 +
|-
 +
|align=center|8||[[NET_OBJ_REF]]||Entity Information field 1||colspan="2"|Directory Number.
 
|-
 
|-
 
|}
 
|}

Revision as of 14:04, 20 June 2007

STATUS_REPORT 0x0072 114 AMC 07.30
Report equipment Presence and Error/OK status for Subscriber Lines, Audio Links, Devices, Boards, etc. Intended for remote logging and external monitoring systems.

As the message is very general, the message definition will be followed by a detailed example of how the different parameters are used for each “entity” type. Unused parameters/flags are always set to 0.

1 NET_OBJ_REF<br\> {ECL_STATION,<br\> ECL_AUDIO_RING,<br\> ECL_AUDIO_LINK,<br\> ECL_BOARD,<br\> ECL_DEVICE,<br\> ECL_NODE} Entity Reference to the Station / Inter­Exchange Link / ICC Audio Ring / Board / Device / Exchange the status message is for.<br\>The entity number is a logical number, e.g. station from 1 to 552.
2 NET_OBJ_REF<br\> {NRF_PHYS_ADDR} Physical address for the entity defined in parameter 1.<br\>This is a hardware module/board/port type of information.
3 BITMAP[1..8] (Error) State Flags.<br\>Bit 1 = Interface present:<br\>Bit 2 = Interface test:<br\>Bit 4 = Signaling test:
Bit 6 = Audio test:<br\>Bit 7 = Device dependent test
 <br\>Board present in exchange<br\>Board reports entity missing/down<br\>Last signaling test failed<br\>Last audio (tone) test failed<br\> 
4 BITMAP[1..8] (State) Change Flags.<br\>Each bit is set if the corresponding state flag bit was changed from the previous report and cleared if it was unchanged.
5 BITMAP[1..8] Reporting Flags.<br\>Bit 8 = VERBOSE. The report is from a manually/externally started test, where the user wants a complete report.
6 UINT1 Extra (Error) Status Information 1.
7 UINT1 Extra (Error) Status Information 2.
8 NET_OBJ_REF<br\>(optional) Entity Information field 1.<br\>.
STATUS_REPORT for Stations:
1 NET_OBJ_REF Station from 1 to 552.<br\>The Sub Class field specifies the type of station interface (TouchLine, Telephone).<br\>Status info. can have different meaning for each Sub Class.
2 NET_OBJ_REF Physical address: Module/board/port.<br\>The (Implicit Type) Resource Address format is used
3 BITMAP[1..8] (Error) State Flags.<br\>Bit 1 = Interface present:<br\>Bit 2 = Interface test:<br\>Bit 6 = Audio test:<br\>Bit 7 = Device dep. test: ---What is reported for Stations:---<br\>ASLT/ATLB board missing <br\>ASLT/ATLB wire monitoring<br\>Tone Test <br\>Handset Off-Hook timeout (no active report)<br\>(only failures)<br\>(only changes)<br\>(only failures)
5 BITMAP[1..8] Reporting Flags.<br\>Bit 8 = VERBOSE.  <br\>Set by Tone Test started from station.
6 UINT1 Status information 1. Bits describing ab- and cd- wire errors
7 UINT1 Status information 2. TouchLine: Tone test signal/noise value.<br\>Telephone: Wire monitor current.
8 NET_OBJ_REF Entity Information field 1 Directory Number.