Actions

Difference between revisions of "MRBD - Relay Board"

From Zenitel Wiki

Line 1: Line 1:
 
[[Image:99702 RS.jpg|thumb|450px|The MRBD board]]
 
[[Image:99702 RS.jpg|thumb|450px|The MRBD board]]
  
== Highlights ==
+
===<u>Highlights</u>===
 
* Equipped with 6 dual changeover relays and relay drivers
 
* Equipped with 6 dual changeover relays and relay drivers
 
* Powered by +24 VDC
 
* Powered by +24 VDC
Line 10: Line 10:
 
** 1,25A is maximum carrying current, maximum switching current at 125VAC is 0,5A. (approx. 60W).
 
** 1,25A is maximum carrying current, maximum switching current at 125VAC is 0,5A. (approx. 60W).
  
 +
===<u>[http://www.zenitel.com/product/mrbd Additional Documentation on Zenitel.com]</u>===
  
==Additional Documentation==
+
===<u>Connectors and Switches ==
For more documentation please see http://www.zenitel.com/product/product/mrbd
 
 
 
== Connectors and Switches ==
 
 
[[image:MRBD-1.PNG|thumb|left|600px|Connectors and switches on MRBD board]]
 
[[image:MRBD-1.PNG|thumb|left|600px|Connectors and switches on MRBD board]]
 
<br style="clear:both;" />
 
<br style="clear:both;" />
Line 20: Line 18:
 
The jumpers S1-S6 determine if the RCO should be activated by a high or low level. High level is used in AlphaCom system, while low level was used in the previous TouchLine generation of intercom system.
 
The jumpers S1-S6 determine if the RCO should be activated by a high or low level. High level is used in AlphaCom system, while low level was used in the previous TouchLine generation of intercom system.
  
== Connections ==
+
===<u>Connections</u>===
=== AlphaCom XE7 ===
+
====AlphaCom XE7====
 
In the XE7 the cable is connected to the 8-pin pinheader labeled '''RCO 1-6''' or '''RCO 7-12'''.
 
In the XE7 the cable is connected to the 8-pin pinheader labeled '''RCO 1-6''' or '''RCO 7-12'''.
  
Line 29: Line 27:
 
<br style="clear:both;" />
 
<br style="clear:both;" />
  
=== AlphaCom XE20/26 ===
+
====AlphaCom XE20/26====
  
 
[[File:RCO XE20.PNG|thumb|500px|left|Connection of MRBD in an AlphaCom XE20]]
 
[[File:RCO XE20.PNG|thumb|500px|left|Connection of MRBD in an AlphaCom XE20]]
Line 37: Line 35:
 
In an AlphaCom XE26 the 24VDC power is provided by the [[PDB|Power Distribution Board PDB]].
 
In an AlphaCom XE26 the 24VDC power is provided by the [[PDB|Power Distribution Board PDB]].
  
==Related Articles==
+
===<u>Related Articles</u>===
 
*[[Turbine Compact and MRBD]]
 
*[[Turbine Compact and MRBD]]
  
 
[[Category:Additional equipment]]
 
[[Category:Additional equipment]]

Revision as of 14:13, 3 November 2016

The MRBD board

Highlights

  • Equipped with 6 dual changeover relays and relay drivers
  • Powered by +24 VDC
  • Connector for 6 RCOs + 2 GND reference signals
  • Connects to the AlphaCom Subscriber Connection Board through a 1:1 cable
  • Fastens onto mounting rail in AlphaCom exchange
  • Relay switching capacity: 125VDC/AC, 1.25A.
    • 1,25A is maximum carrying current, maximum switching current at 125VAC is 0,5A. (approx. 60W).

Additional Documentation on Zenitel.com

=Connectors and Switches

Connectors and switches on MRBD board


The jumpers S1-S6 determine if the RCO should be activated by a high or low level. High level is used in AlphaCom system, while low level was used in the previous TouchLine generation of intercom system.

Connections

AlphaCom XE7

In the XE7 the cable is connected to the 8-pin pinheader labeled RCO 1-6 or RCO 7-12.

  • An ASLT board in board position 1 is required to operate RCO 1 - 6.
  • An ASLT board in board position 2 is required to operate RCO 7 - 12.
Connection of MRBD in an AlphaCom XE7


AlphaCom XE20/26

Connection of MRBD in an AlphaCom XE20



In an AlphaCom XE26 the 24VDC power is provided by the Power Distribution Board PDB.

Related Articles