The AMC configuration will be set to factory default (autoload) by one of the following actions: | The AMC configuration will be set to factory default (autoload) by one of the following actions: | ||
− | * Pressing the coldstart button of the AMC-IP in combination with reset button. Reset button is located on the power board in the AlphaCom E7 and on the APC board in AlphaCom E20 and AlphaCom E26 | + | * Pressing the [[Cold Start of AMC-IP|coldstart button of the AMC-IP]] in combination with reset button. Reset button is located on the power board in the AlphaCom E7 and on the APC board in AlphaCom E20 and AlphaCom E26 |
* From AlphaWeb: System Maintenance -> System Recovery -> Load Factory Defaults | * From AlphaWeb: System Maintenance -> System Recovery -> Load Factory Defaults | ||
* When upgrading the AMC software and the AMC Database versions are different, the running intercom configuration will automatically be deleted and factory default settings will be generated. E.g. an upgrade within version 10.0x (say 10.04 to 10.05) will keep the configuration, but an upgrade from 10.0x to 10.2.x (say 10.05 to 10.22) will set the configuration to factory defaults. | * When upgrading the AMC software and the AMC Database versions are different, the running intercom configuration will automatically be deleted and factory default settings will be generated. E.g. an upgrade within version 10.0x (say 10.04 to 10.05) will keep the configuration, but an upgrade from 10.0x to 10.2.x (say 10.05 to 10.22) will set the configuration to factory defaults. |
Revision as of 12:02, 10 January 2008
Autoload or 'cold start' means loading factory default settings.
- Cold Start of AMC-IP (AlphaCom E)
- Cold Start of AMC (AlphaCom)
- Load factory defaults on IP Substation
The AMC configuration will be set to factory default (autoload) by one of the following actions:
- Pressing the coldstart button of the AMC-IP in combination with reset button. Reset button is located on the power board in the AlphaCom E7 and on the APC board in AlphaCom E20 and AlphaCom E26
- From AlphaWeb: System Maintenance -> System Recovery -> Load Factory Defaults
- When upgrading the AMC software and the AMC Database versions are different, the running intercom configuration will automatically be deleted and factory default settings will be generated. E.g. an upgrade within version 10.0x (say 10.04 to 10.05) will keep the configuration, but an upgrade from 10.0x to 10.2.x (say 10.05 to 10.22) will set the configuration to factory defaults.
- A default AlphaPro database is sent to the exchange
In addition a system will return to factory default settings if:
- A Master backup 7821 is (accidentally) done on an autoloaded system. A master backup is automatically restored after exchange reset or power on.