External Data Input: Difference between revisions
From Zenitel Wiki
No edit summary |
|||
| Line 46: | Line 46: | ||
The rule below will allow you to issue commands to EDI port like this: | The rule below will allow you to issue commands to EDI port like this: | ||
*connect,101,103 | * Input command: '''connect,101,103''' | ||
:-Generates internal command '''$CALL L101 L103''' | :-Generates internal command '''$CALL L101 L103''' | ||
*disconnect,101,103 | *Input command: '''disconnect,101,103''' | ||
:-Generates internal commands '''$C L101'''and '''$C L103''' | :-Generates internal commands '''$C L101'''and '''$C L103''' | ||
Revision as of 16:07, 31 August 2007
Event description
| Event Owner: | EDI Text Config |
|---|---|
| Event type: | 28 - External Data Input |
| Sub-Event: | 1 – 4: specifies which EDI port. 0: matches all ports |
| When Change to ON: | When valid data is received on EDI port |
| When Change to OFF: | N/A |
| When Related to: | N/A |
- Input message
- - The EDI port is defined in the ‘Serial Ports’ Setup
- - The input message must have a termination character. Max 128 char.
- - Parsing the content is done in the action string
- Context parameters
- Useful macros and statements
Example
The rule below will allow you to issue commands to EDI port like this:
- Input command: connect,101,103
- -Generates internal command $CALL L101 L103
- Input command: disconnect,101,103
- -Generates internal commands $C L101and $C L103
evh add edi 0 tmp 0 "%scutf(%edi,\,,0)" tmp 1 "%scutf(%edi,\,,1)" tmp 2 "%scutf(%edi,\,,2)" if %scmp(%tmp(0),connect) $call l%tmp(1) l%tmp(2) stop endif if %scmp(%tmp(0),disconnect) $c l%tmp(1) $c l%tmp(2) stop endif