Difference between revisions of "External Data Input"
From Zenitel Wiki
(→Example) |
|||
Line 46: | Line 46: | ||
The rule below will allow you to issue commands to EDI port like this: | The rule below will allow you to issue commands to EDI port like this: | ||
− | *connect,101,103 | + | * Input command: '''connect,101,103''' |
:-Generates internal command '''$CALL L101 L103''' | :-Generates internal command '''$CALL L101 L103''' | ||
− | *disconnect,101,103 | + | *Input command: '''disconnect,101,103''' |
:-Generates internal commands '''$C L101'''and '''$C L103''' | :-Generates internal commands '''$C L101'''and '''$C L103''' | ||
Revision as of 16:07, 31 August 2007
Event description
Event Owner: | EDI Text Config |
---|---|
Event type: | 28 - External Data Input |
Sub-Event: | 1 – 4: specifies which EDI port. 0: matches all ports |
When Change to ON: | When valid data is received on EDI port |
When Change to OFF: | N/A |
When Related to: | N/A |
- Input message
- - The EDI port is defined in the ‘Serial Ports’ Setup
- - The input message must have a termination character. Max 128 char.
- - Parsing the content is done in the action string
- Context parameters
- Useful macros and statements
Example
The rule below will allow you to issue commands to EDI port like this:
- Input command: connect,101,103
- -Generates internal command $CALL L101 L103
- Input command: disconnect,101,103
- -Generates internal commands $C L101and $C L103
evh add edi 0 tmp 0 "%scutf(%edi,\,,0)" tmp 1 "%scutf(%edi,\,,1)" tmp 2 "%scutf(%edi,\,,2)" if %scmp(%tmp(0),connect) $call l%tmp(1) l%tmp(2) stop endif if %scmp(%tmp(0),disconnect) $c l%tmp(1) $c l%tmp(2) stop endif