Actions

Difference between revisions of "IP Substation - Amplified calling"

From Zenitel Wiki

Line 12: Line 12:
 
[[Image:WK and IP sub M control.png|thumb|Amplified calling - amplifier controlled by M-key]]
 
[[Image:WK and IP sub M control.png|thumb|Amplified calling - amplifier controlled by M-key]]
 
=== Amplifier controlled by relay ===
 
=== Amplifier controlled by relay ===
The amplifier can be switched on and off by the relay on the IP substation. The [[IP_Station_Configuration#RCO_-_Remote_Control_Output|relay]] is controlled by the [[RCO command|RCO]] in the [[Event Handler]].
+
The amplifier can be switched on and off by the relay on the IP substation. The [[IP_Station_Configuration#RCO_-_Remote_Control_Output|relay]] is controlled by the [[RCO]] in the [[Event Handler]].
  
 
<br style="clear:both;" />
 
<br style="clear:both;" />

Revision as of 17:08, 28 November 2008

This article describes how to connect an external amplifier to the line output of the IP substation.

Power Amplifier 1000614100

Amplified calling - amplifier constantly on

Amplifier constanly on

The power amplifier is controlled through input 1 and 2. To make the amplifier constanly on:

  • Strap point 2 and 3
  • Strap point 1 and 7

When the amplifier is constanly on some humming might be heard in the speaker in idle.

Amplified calling - amplifier controlled by M-key

Amplifier controlled by relay

The amplifier can be switched on and off by the relay on the IP substation. The relay is controlled by the RCO in the Event Handler.