== Power Amplifier 1000614100 == | == Power Amplifier 1000614100 == | ||
[[Image:WK and IP sub.png|thumb|Amplified calling - amplifier constantly on]] | [[Image:WK and IP sub.png|thumb|Amplified calling - amplifier constantly on]] | ||
− | The [[WK20 - 20W Power Amplifier|amplifier 1000614100]] is very well suited to amplify the audio of a Stentofon station. | + | The [[WK20 - 20W Power Amplifier|amplifier 1000614100]] is very well suited to amplify the audio of a Stentofon station. The amplifier can be used together with both IP stations and analog stations. |
=== Amplifier constanly on === | === Amplifier constanly on === | ||
The power amplifier is controlled through input 1 and 2. By strapping one can make the amplifier constanly on: | The power amplifier is controlled through input 1 and 2. By strapping one can make the amplifier constanly on: |
Revision as of 17:46, 28 November 2008
This article describes how to connect an external amplifier to the line output of the IP substation.
Contents
Power Amplifier 1000614100
The amplifier 1000614100 is very well suited to amplify the audio of a Stentofon station. The amplifier can be used together with both IP stations and analog stations.
Amplifier constanly on
The power amplifier is controlled through input 1 and 2. By strapping one can make the amplifier constanly on:
- Strap point 2 and 3
- Strap point 1 and 7
No programming is required.
Note: When the amplifier is constanly on some humming might be heard in the speaker in idle.
Amplifier controlled by relay
The amplifier can be switched on and off by the relay in the IP substation. The relay is controlled by the RCO command in the Event Handler.
Configure the relay operation:
- In Exchange & System -> RCO, map a free RCO to the relay of the station.
- In Users & Stations select the IP station in the list box, and press the button 'Events'. 'Insert' a new event with the following attributes:
Event Owner: | The IP station |
Event type: | 1 - Audio |
Subevent: | 126 (Press 'Details' to select which types of audio. 126 means all types of audio) |
When change to: | ON or OFF |
When related to: | (not used) |
Action: | RCO 10 |
RCO 10 is used as an example. Use the RCO number you have assigned to the IP substation relay.