Difference between revisions of "Station ID for MLH/CRM feature"
From Zenitel Wiki
Line 1: | Line 1: | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
{| | {| | ||
|- | |- | ||
Line 23: | Line 10: | ||
|'''Parameter 1''': || 0 (N/A) | |'''Parameter 1''': || 0 (N/A) | ||
|-valign="top" | |-valign="top" | ||
− | |'''Description''': || Some Control Room stations based on | + | |'''Description''': || Some Control Room stations based on the [[MPC Data Protocol]] must be told automatically what directory number the audio line has. In addition, the station stays in a programming mode where all digits dialled on the keypad are just sent out of the exchange on the TouchLine data protocol. The station then uses this e.g. to program dialler keys. |
Procedure: Dial 786. A success tone is heard, and the station LED blinks two times rapidly (double-blink), then waits for digits. The feature is cancelled with the C key. | Procedure: Dial 786. A success tone is heard, and the station LED blinks two times rapidly (double-blink), then waits for digits. The feature is cancelled with the C key. | ||
− | + | Data generated on the [[MPC Data Protocol]]: | |
− | + | *0507 AAAA F786 0000 0000 | |
− | + | *0210 AAAA | |
|} | |} | ||
[[AlphaCom Feature List|Back to feature list]] | [[AlphaCom Feature List|Back to feature list]] |
Revision as of 20:23, 8 January 2008
Feature: | Station ID for MLH/CRM |
Default directory number: | 786 |
Feature number: | 43 |
Parameter 1: | 0 (N/A) |
Description: | Some Control Room stations based on the MPC Data Protocol must be told automatically what directory number the audio line has. In addition, the station stays in a programming mode where all digits dialled on the keypad are just sent out of the exchange on the TouchLine data protocol. The station then uses this e.g. to program dialler keys.
Procedure: Dial 786. A success tone is heard, and the station LED blinks two times rapidly (double-blink), then waits for digits. The feature is cancelled with the C key. Data generated on the MPC Data Protocol:
|